• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

5504.3.1.2.1 Exposure Hazard Separation

California Fire Code 2019 > 55 Cryogenic Fluids > 5504 Storage > 5504.3 Outdoor Storage > 5504.3.1 Separation From Hazardous Conditions > 5504.3.1.2 Outdoor Storage of Portable Containers > 5504.3.1.2.1 Exposure Hazard Separation
JUMP TO FULL CODE CHAPTER

Portable containers in outdoor storage shall be separated from exposure hazards in accordance with Table 5504.3.1.2.1.

TABLE 5504.3.1.2.1

SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS

EXPOSURE MINIMUM DISTANCE
(feet)
Building exits 10
Wall openings 1
Air intakes 10
Lot lines 5
Combustible materials such as paper,
leaves, weeds, dry grass or debris
15
Other hazardous materials In accordance with
Chapter 50

For SI: 1 foot = 304.8 mm.

Related Code Sections


5504.3.1.2.1 Cryogenic Fluids, Exposure Hazard Separation
Portable containers in outdoor storage shall be separated from exposure hazards in accordance with Table 5504.3.1.2.1. TABLE 5504.3.1.2.1 ...
California Fire Code 2019 > 55 Cryogenic Fluids > 5504 Storage > 5504.3 Outdoor Storage > 5504.3.1 Separation From Hazardous Conditions > 5504.3.1.2 Outdoor Storage of Portable Containers > 5504.3.1.2.1 Exposure Hazard Separation
5504.3.1.2.1 Cryogenic Fluids, Exposure Hazard Separation
Portable containers in outdoor storage shall be separated from exposure hazards in accordance with Table 5504.3.1.2.1. TABLE 5504.3.1.2.1 ...
California Fire Code 2016 > 55 Cryogenic Fluids > 5504 Storage > 5504.3 Outdoor Storage > 5504.3.1 Separation From Hazardous Conditions > 5504.3.1.2 Outdoor Storage of Portable Containers > 5504.3.1.2.1 Exposure Hazard Separation
5504.3.1.2 Cryogenic Fluids, Outdoor Storage of Portable Containers
Portable containers in outdoor storage shall be separated from exposure hazards ...
California Fire Code 2016 > 55 Cryogenic Fluids > 5504 Storage > 5504.3 Outdoor Storage > 5504.3.1 Separation From Hazardous Conditions > 5504.3.1.2 Outdoor Storage of Portable Containers
Section 5504 Cryogenic Fluids, Storage
Cryogenic containers and systems in outdoor storage shall be separated from materials and conditions that pose exposure hazards to or from ...
California Fire Code 2016 > 55 Cryogenic Fluids > 5504 Storage
Section 5504 Cryogenic Fluids, Storage
Cryogenic containers and systems in outdoor storage shall be separated from materials and conditions that pose exposure hazards to or from ...
California Fire Code 2019 > 55 Cryogenic Fluids > 5504 Storage
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE