• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E3802.3 Exposed Cable

2015 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable
JUMP TO FULL CODE CHAPTER
In exposed work, except as provided for in Sections E3802.2 and E3802.4, cable assemblies shall be installed as specified in Sections E3802.3.1 and E3802.3.2. (330.15 and 334.15)

E3802.3.1 Surface Installation

Cables shall closely follow the surface of the building finish or running boards. [334.15(A)]

E3802.3.2 Protection From Physical Damage

Where subject to physical damage, cables shall be protected by rigid metal conduit, intermediate metal conduit, electrical metallic tubing, Schedule 80 PVC rigid nonmetallic conduit, or other approved means. Where passing through a floor, the cable shall be enclosed in rigid metal conduit, intermediate metal conduit, electrical metallic tubing, Schedule 80 PVC rigid nonmetallic conduit or other approved means extending not less than 6 inches (152 mm) above the floor. [334.15(B)]

E3802.3.3 Locations Exposed to Direct Sunlight

Insulated conductors and cables used where exposed to direct rays of the sun shall be listed or listed and marked, as being "sunlight resistant," or shall be covered with insulating material, such as tape or sleeving, that is listed or listed and marked as being "sunlight resistant." [310.10(D)]

Related Code Sections


E3802.3 Wiring Methods, Exposed Cable
In exposed work, except as provided for in Sections E3802.2 and E3802.4, cable assemblies shall be installed as specified in Sections E3802.3.1 ...
2015 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable
E3802.3 Wiring Methods, Exposed Cable
In exposed work, except as provided for in Sections E3802.2 and E3802.4, cable assemblies shall be installed as specified in Sections E3802.3.1 ...
2012 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable
E3802.3.1 Wiring Methods, Surface Installation
Cables shall closely follow the surface of the building finish or running boards. [334.15(A)] ...
2015 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable > E3802.3.1 Surface Installation
E3605.6 Services, Locations Exposed to Direct Sunlight
Insulated conductors and cables used where exposed to direct rays of the sun shall comply with one of the following: The conductors and cables ...
2012 Virginia Residential Code > 36 Services > E3605 Service-Entrance Conductors > E3605.6 Locations Exposed to Direct Sunlight
E3605.6 Services, Locations Exposed to Direct Sunlight
Insulated conductors and cables used where exposed to direct rays of the sun shall comply with one of the following: The conductors and cables ...
2015 Virginia Residential Code > 36 Services > E3605 Service-Entrance Conductors > E3605.6 Locations Exposed to Direct Sunlight
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE