E3802.3 Exposed Cable
JUMP TO FULL CODE CHAPTER
Cables shall closely follow the surface of the building finish or running boards. [334.15(A)]
Where subject to physical damage, cables shall be protected by rigid metal conduit, intermediate metal conduit, electrical metallic tubing, Schedule 80 PVC rigid nonmetallic conduit, or other approved means. Where passing through a floor, the cable shall be enclosed in rigid metal conduit, intermediate metal conduit, electrical metallic tubing, Schedule 80 PVC rigid nonmetallic conduit or other approved means extending not less than 6 inches (152 mm) above the floor. [334.15(B)]
Insulated conductors and cables used where exposed to direct rays of the sun shall be listed or listed and marked, as being "sunlight resistant," or shall be covered with insulating material, such as tape or sleeving, that is listed or listed and marked as being "sunlight resistant." [310.10(D)]
Related Code Sections
E3802.3 Wiring Methods, Exposed Cable
In exposed work, except as provided for in Sections E3802.2 and E3802.4, cable assemblies shall be installed as specified in Sections E3802.3.1 ...
2015 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable
E3802.3 Wiring Methods, Exposed Cable
In exposed work, except as provided for in Sections E3802.2 and E3802.4, cable assemblies shall be installed as specified in Sections E3802.3.1 ...
2012 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable
E3802.3.1 Wiring Methods, Surface Installation
Cables shall closely follow the surface of the building finish or running boards. [334.15(A)] ...
2015 Virginia Residential Code > 38 Wiring Methods > E3802 Above-Ground Installation Requirements > E3802.3 Exposed Cable > E3802.3.1 Surface Installation
E3605.6 Services, Locations Exposed to Direct Sunlight
Insulated conductors and cables used where exposed to direct rays of the sun shall comply with one of the following: The conductors and cables ...
2012 Virginia Residential Code > 36 Services > E3605 Service-Entrance Conductors > E3605.6 Locations Exposed to Direct Sunlight
E3605.6 Services, Locations Exposed to Direct Sunlight
Insulated conductors and cables used where exposed to direct rays of the sun shall comply with one of the following: The conductors and cables ...
2015 Virginia Residential Code > 36 Services > E3605 Service-Entrance Conductors > E3605.6 Locations Exposed to Direct Sunlight