// CODE SNIPPET
1015.1 Exits or Exit Access Doorways From Spaces
JUMP TO FULL CODE CHAPTER
Two exits or exit access doorways from any space shall be provided where one of the following conditions exists:
- The occupant load of the space exceeds one of the values in Table 1015.1.
Exceptions:
- In Group R-2 and R-3 occupancies, one means of egress is permitted within and from individual dwelling units with a maximum occupant load of 20 where the dwelling unit is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2.
- Care suites in Group I-2 occupancies complying with Section 407.4.3.
- The common path of egress travel exceeds one of the limitations of Section 1014.3.
- Where required by Section 1015.3, 1015.4, 1015.5, or 1015.6.
OCCUPANCY | MAXIMUM OCCUPANT LOAD |
A, B, E, F, M, U | 49 |
H-1, H-2, H-3 | 3 |
H-4, H-5, I-1, I-2, I-3, I-4, R | 10 |
S | 29 |
Three exits or exit access doorways shall be provided from any space with an occupant load of 501 to 1,000. Four exits or exit access doorways shall be provided from any space with an occupant load greater than 1,000.
Related Code Sections
1015.1 Means of Egress, Exits or Exit Access Doorways From Spaces
Two exits or exit access doorways from any space shall be provided where one of the following conditions exists:
The occupant load ...
Building Code 2012 of South Holland, IL > 10 Means of Egress > 1015 Exit and Exit Access Doorways > 1015.1 Exits or Exit Access Doorways From Spaces
1015.1 Means of Egress, Exits or Exit Access Doorways From Spaces
Two exits or exit access doorways from any space shall be provided where one of the following conditions exists:
The occupant load ...
Fire Code 2012 of South Holland, IL > 10 Means of Egress > 1015 Exit and Exit Access Doorways > 1015.1 Exits or Exit Access Doorways From Spaces
1004.3 Means of Egress, Posting of Occupant Load
exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained ...
Fire Code 2012 of South Holland, IL > 10 Means of Egress > 1004 Occupant Load > 1004.3 Posting of Occupant Load
1004.3 Means of Egress, Posting of Occupant Load
exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained ...
Building Code 2012 of South Holland, IL > 10 Means of Egress > 1004 Occupant Load > 1004.3 Posting of Occupant Load
402.8.6 Special Detailed Requirements Based on Use and Occupancy, Access to Exits
space, doorways to the exit passageway shall be protected by 1-hour fire door assemblies that are self- or automatic-closing by smoke detection ...
Building Code 2012 of South Holland, IL > 4 Special Detailed Requirements Based on Use and Occupancy > 402 Covered Mall and Open Mall Buildings > 402.8 Means of Egress > 402.8.6 Access to Exits