• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-367 Exit Reduction

NYC 1968 Code (Vol I) > 6 Means of Egress > 4 Number of Exits > §27-367 Exit Reduction
JUMP TO FULL CODE CHAPTER
When a floor area has access to areas of refuge that comply with the requirements of section 27-372 of article five of this subchapter, the number of persons for whom vertical exits are to be provided may be reduced to fifty per cent of the occupant load of the floor area when one area of refuge is provided, and may be reduced to thirty-three and one-third per cent of the floor area when two areas of refuge are provided. This section shall not be applicable to any new or altered place of assembly, except for such places of assembly in fully sprinklered office buildings which occupy less than twenty percent of the floor area occupied by the principal use.

Related Code Sections


§27-367 Means of Egress, Exit Reduction
of persons for whom vertical exits are to be provided may be reduced to fifty per cent of the occupant load of the floor area when one area of refuge ...
NYC 1968 Code (Vol I) > 6 Means of Egress > 4 Number of Exits > §27-367 Exit Reduction
1023.5.1 Means of Egress, Width
and the width of such egress court is then reduced along the path of exit travel, the reduction in width shall be gradual. The transition in width ...
NYC Building Code 2008 > 10 Means of Egress > 1023 Exit Discharge > 1023.5 Egress Courts > 1023.5.1 Width
1027.5.1 Means of Egress, Width
exceeds the minimum required width and the width of such egress court is then reduced along the path of exit travel, the reduction in width shall ...
NYC Building Code 2014 > 10 Means of Egress > 1027 Exit Discharge > 1027.5 Egress Courts > 1027.5.1 Width
§28-101.4.4 Administration, Reductions of Fire Safety or Structural Safety of Prior Code Buildings Prohibited
of this code would result in a reduction of the fire safety or structural safety of such building, relevant provisions of the 1968 building code shall apply ...
NYC General Admin. Provisions 2014 > 1 Administration > 101 General > §28-101.4 Effective Date > §28-101.4.4 Reductions of Fire Safety or Structural Safety of Prior Code Buildings Prohibited
Article 7 Means of Egress [PDF] (page 7)
occupants, shall be provided with such means of egress consisting of fire-escapes or such other means of egress or fire protection ...
NYC 1938 Code [PDF] > 7 Means of Egress
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE