• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3103.12.3 Exit Openings From Tents

Minnesota Fire Code 2015 > 31 Tents and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.12 Means of Egress > 3103.12.3 Exit Openings From Tents
JUMP TO FULL CODE CHAPTER
Exit openings from tents shall remain open unless covered by a flame-resistant curtain. The curtain shall comply with the following requirements:
  1. Curtains shall be free sliding on a metal support. The support shall be a minimum of 80 inches (2032 mm) above the floor level at the exit. The curtains shall be so arranged that, when open, no part of the curtain obstructs the exit.
  2. Curtains shall be of a color, or colors, that contrasts with the color of the tent.

Related Code Sections


3103.12.3 Tents, Temporary Special Event Structures and Other Membrane Structures, Exit Openings From Tents
Exit openings from tents shall remain open unless covered by a flame-resistant curtain. The curtain shall comply with the following requirements ...
2020 Minnesota State Fire Code > 31 Tents, Temporary Special Event Structures and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.12 Means of Egress > 3103.12.3 Exit Openings From Tents
3103.12.3 Tents and Other Membrane Structures, Exit Openings From Tents
Exit openings from tents shall remain open unless covered by a flame-resistant curtain. The curtain shall comply with the following requirements ...
Minnesota Fire Code 2015 > 31 Tents and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.12 Means of Egress > 3103.12.3 Exit Openings From Tents
3103.8 Tents, Temporary Special Event Structures and Other Membrane Structures, Access, Location and Parking
square feet (1394 m 2 ). Membrane structures or tents need not be separated from buildings where all of the following conditions are met: 2.1. The ...
2020 Minnesota State Fire Code > 31 Tents, Temporary Special Event Structures and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.8 Access, Location and Parking
3103.12.6 Tents and Other Membrane Structures, Exit Signs
Exits shall be clearly marked. Exit signs shall be installed at required exit doorways and where otherwise necessary to indicate clearly ...
Minnesota Fire Code 2015 > 31 Tents and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.12 Means of Egress > 3103.12.6 Exit Signs
3103.12.6 Tents, Temporary Special Event Structures and Other Membrane Structures, Exit Signs
Exits shall be clearly marked. Exit signs shall be installed at required exit doorways and where otherwise necessary to indicate clearly ...
2020 Minnesota State Fire Code > 31 Tents, Temporary Special Event Structures and Other Membrane Structures > 3103 Temporary Tents and Membrane Structures > 3103.12 Means of Egress > 3103.12.6 Exit Signs
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE