3102.10.2 Exit Openings From Air-Supported Structures and Air-Inflated Structures
JUMP TO FULL CODE CHAPTER
Exit doors in air-supported structures and air-inflated structures shall close automatically against normal operational pressures. Opening force at the edge of such doors shall not exceed 15 pounds (6.80 kg), with the structure at operational pressure. Exit doors shall be located in frames constructed such that they will remain operative and support the weight of the pressurized membrane structure in a state of total collapse.
Related Code Sections
3102.10.2 Special Construction, Exit Openings From Air-Supported Structures and Air-Inflated Structures
Exit doors in air-supported structures and air-inflated structures shall close automatically against normal operational pressures. Opening force ...
NYC Building Code 2008 > 31 Special Construction > 3102 Membrane Structures > 3102.10 Exits > 3102.10.2 Exit Openings From Air-Supported Structures and Air-Inflated Structures
3102.10.2 Special Construction, Exit Openings From Air-Supported Structures and Air-Inflated Structures
Exit doors in air-supported structures and air-inflated structures shall close automatically against normal operational pressures. Opening force ...
NYC Building Code 2014 > 31 Special Construction > 3102 Membrane Structures > 3102.10 Exits > 3102.10.2 Exit Openings From Air-Supported Structures and Air-Inflated Structures
Article 19 Special Uses and Occupancies, Tents and Air-Supported Structures
for separation from other buildings on the site shall be waived where a tent or air-supported structure is used for on-site temporary shelter for construction ...
3102.8 Special Construction, Inflation Systems
Air-supported structures and air-inflated structures shall be provided with primary and auxiliary inflation systems to meet the minimum requirements ...
NYC Building Code 2014 > 31 Special Construction > 3102 Membrane Structures > 3102.8 Inflation Systems
3102.8.3 Special Construction, Support Provisions
A system capable of supporting the membrane in the event of deflation shall be provided for in air-supported structures and air-inflated structures ...
NYC Building Code 2014 > 31 Special Construction > 3102 Membrane Structures > 3102.8 Inflation Systems > 3102.8.3 Support Provisions