• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1803.13.1.4 Exit Access Corridors

2010 Fire Code of NY > 18 Semiconductor Fabrication Facilities > 1803 General Safety Provisions > 1803.13 Continuous Gas Detection Systems > 1803.13.1 Where Required > 1803.13.1.4 Exit Access Corridors
JUMP TO FULL CODE CHAPTER
When gases are transported in piping placed within the space defined by the walls of an exit access corridor and the floor or roof above the exit access corridor, a continuous gas detection system shall be provided where piping is located and in the exit access corridor.
Exception: A continuous gas detection system is not required for occasional transverse crossings of the corridors by supply piping which is enclosed in a ferrous pipe or tube for the width of the corridor.

Related Code Sections


1803.13.1.4 Semiconductor Fabrication Facilities, Exit Access Corridors
When gases are transported in piping placed within the space defined by the walls of an exit access corridor and the floor or roof above the exit ...
2010 Fire Code of NY > 18 Semiconductor Fabrication Facilities > 1803 General Safety Provisions > 1803.13 Continuous Gas Detection Systems > 1803.13.1 Where Required > 1803.13.1.4 Exit Access Corridors
1805.3.1 Semiconductor Fabrication Facilities, Exit Access Corridors and Exit Enclosures
Exit access corridors and exit enclosures in new buildings or serving new fabrication areas shall not contain HPM except as permitted for exit access ...
2010 Fire Code of NY > 18 Semiconductor Fabrication Facilities > 1805 Use and Handling > 1805.3 Transportation and Handling > 1805.3.1 Exit Access Corridors and Exit Enclosures
415.8.4.6.2 Special Detailed Requirements Based on Use and Occupancy, Exit Access Corridors and Exit Enclosures
Emergency alarms for exit access corridors and exit enclosures shall comply with Section 414.7.2 ...
2010 Building Code of NY > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.8 Group H-5 > 415.8.4 Service Corridors > 415.8.4.6 Emergency Alarm System > 415.8.4.6.2 Exit Access Corridors and Exit Enclosures
2703.3.2 Semiconductor Fabrication Facilities, Pass-Throughs in Exit Access Corridors
Pass-throughs in exit access corridors shall be constructed in accordance with the International Building Code ...
Fire Code 2015 of New York State > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.3 Construction Requirements > 2703.3.2 Pass-Throughs in Exit Access Corridors
2703.3.2 Semiconductor Fabrication Facilities, Pass-Throughs in Exit Access Corridors
Pass-throughs in exit access corridors shall be constructed in accordance with the Building Code of New York State ...
2020 Fire Code of NYS > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.3 Construction Requirements > 2703.3.2 Pass-Throughs in Exit Access Corridors
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE