// CODE SNIPPET
1014.2.4.2 Exit Access
JUMP TO FULL CODE CHAPTER
Any room or suite of rooms, other than patient sleeping rooms, of more than 2,500 square feet (232 m2) shall have at least two exit access doors remotely located from each other.
Related Code Sections
Section 1013 Means of Egress, Exit Access
The exit access arrangement shall comply with Sections 1013 through 1016 and the applicable provisions of Sections 1003 through 1012 ...
Section 1014 Means of Egress, Exit Access
The exit access shall comply with the applicable provisions of Sections 1003 through 1013. Exit access arrangement shall comply with Sections 1014 ...
3104.9 Special Construction, Exit Access Travel
The length of exit access travel shall not exceed 200 feet (60 960 mm).
Exceptions:
Exit access travel distance on a pedestrian walkway ...
NYC Building Code 2008 > 31 Special Construction > 3104 Pedestrian Walkways and Tunnels > 3104.9 Exit Access Travel
3104.9 Special Construction, Exit Access Travel
The length of exit access travel shall not exceed 200 feet (60 960 mm). Exceptions: Exit access travel distance on a pedestrian walkway ...
NYC Building Code 2014 > 31 Special Construction > 3104 Pedestrian Walkways and Tunnels > 3104.9 Exit Access Travel
415.9.3 Special Detailed Requirements Based on Use and Occupancy, Exit Access Corridors
Exit access corridors shall comply with Chapter 10 and shall be separated from fabrication areas as specified in Section 415.9.2.2. Exit access ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.9 Group H-5 > 415.9.3 Exit Access Corridors