• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BS] A405.3.4 Existing Concrete

2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A405 Materials of Construction > A405.3 Existing Materials > A405.3.4 Existing Concrete
JUMP TO FULL CODE CHAPTER
All existing concrete footings shall be permitted to be assumed to be plain concrete with a compressive strength of 2,000 pounds per square inch (13.8 MPa). Existing concrete compressive strength taken greater than 2,000 pounds per square inch (13.8 MPa) shall be verified by testing, record drawings or department records.

Related Code Sections


A405.3.4 Guidelines for the Seismic Retrofit of Existing Buildings, Existing Concrete
All existing concrete footings shall be permitted to be assumed to be plain concrete with a compressive strength of 2,000 pounds per square inch ...
2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A405 Materials of Construction > A405.3 Existing Materials > A405.3.4 Existing Concrete
A405.3.4 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls, Existing Concrete
All existing concrete footings shall be permitted to be assumed to be plain concrete with a compressive strength of 2,000 pounds per square inch ...
Existing Building Code 2015 of New York State > A4 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls > A405 Materials of Construction > A405.3 Existing Materials > A405.3.4 Existing Concrete
Chapter A5 Earthquake Hazard Reduction in Existing Concrete Buildings
Existing Building Code 2015 of New York State > A5 Earthquake Hazard Reduction in Existing Concrete Buildings
Section A502 Earthquake Hazard Reduction in Existing Concrete Buildings, Scope
The provisions of this chapter shall apply to all buildings having concrete floors or roofs supported by reinforced concrete walls or by concrete ...
Existing Building Code 2015 of New York State > A5 Earthquake Hazard Reduction in Existing Concrete Buildings > A502 Scope
Section A507 Earthquake Hazard Reduction in Existing Concrete Buildings, Tier 3 Analysis Procedure
general assumptions and requirements of Section 10.3 of ASCE 41, excluding those for concrete frames with infills, shall be used in the evaluation ...
Existing Building Code 2015 of New York State > A5 Earthquake Hazard Reduction in Existing Concrete Buildings > A507 Tier 3 Analysis Procedure
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE