G2439.3.1 (614.4.1) Exhaust Termination Outlet and Passageway
JUMP TO FULL CODE CHAPTER
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 mm2).
Related Code Sections
G2439.3.1 Fuel Gas, (614.4.1) Exhaust Termination Outlet and Passageway
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 ...
Residential Code 2018 of Kansas > 24 Fuel Gas > G2439 (614) Clothes Dryer Exhaust > G2439.3 (614.4) Exhaust Installation > G2439.3.1 (614.4.1) Exhaust Termination Outlet and Passageway
614.4.1 Specific Appliances, Exhaust Termination Outlet and Passageway
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 ...
Fuel Gas Code 2018 of Kansas > 6 Specific Appliances > 614 (IFGC) Clothes Dryer Exhaust > 614.4 Exhaust Installation > 614.4.1 Exhaust Termination Outlet and Passageway
504.4.1 Exhaust Systems, Exhaust Termination Outlet and Passageway Size
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.4 Exhaust Installation > 504.4.1 Exhaust Termination Outlet and Passageway Size
M1502.3.1 Exhaust Systems, Exhaust Termination Outlet and Passageway Size
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1502 Clothes Dryer Exhaust > M1502.3 Duct Termination > M1502.3.1 Exhaust Termination Outlet and Passageway Size
511.2 Exhaust Systems, Exhaust Outlets
Outlets for exhaust that exceed 600°F (315°C) shall be designed as a chimney in accordance with Table 511.2. TABLE 511.2 CONSTRUCTION ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 511 Dust, Stock and Refuse Conveying Systems > 511.2 Exhaust Outlets