Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

502.1.1 Exhaust Location

Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 502 Required Systems > 502.1 General > 502.1.1 Exhaust Location
JUMP TO FULL CODE CHAPTER
The inlet to an exhaust system shall be located in the area of heaviest concentration of contaminants.

Related Code Sections


502.1.1 Exhaust Systems, Exhaust Location
The inlet to an exhaust system shall be located in the area of heaviest concentration of contaminants ...
Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 502 Required Systems > 502.1 General > 502.1.1 Exhaust Location
1105.6.1.1 Refrigeration, Indoor Exhaust Opening Location
Indoor mechanical exhaust intake openings shall be located where refrigerant leakage is likely to concentrate based on the refrigerant's relative ...
Mechanical Code 2018 of Maryland > 11 Refrigeration > 1105 Machinery Room, General Requirements > 1105.6 Ventilation > 1105.6.1 Discharge Location > 1105.6.1.1 Indoor Exhaust Opening Location
501.3.1 Exhaust Systems, Location of Exhaust Outlets
The termination point of exhaust outlets and ducts discharging to the outdoors shall be located with the following minimum distances: For ducts ...
Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 501 General > 501.3 Exhaust Discharge > 501.3.1 Location of Exhaust Outlets
507.1.5 Exhaust Systems, Exhaust Outlets
Exhaust outlets located within the hood shall be located so as to optimize the capture of particulate matter. Each outlet shall serve not more than ...
Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 507 Commercial Kitchen Hoods > 507.1 General > 507.1.5 Exhaust Outlets
506.5.1.1 Exhaust Systems, Fan Motor
Exhaust fan motors shall be located outside of the exhaust airstream ...
Mechanical Code 2018 of Maryland > 5 Exhaust Systems > 506 Commercial Kitchen Hood Ventilation System Ducts and Exhaust Equipment > 506.5 Exhaust Equipment > 506.5.1 Exhaust Fans > 506.5.1.1 Fan Motor
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING