Exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. Ducts shall not be connected or installed with sheet metal screws or other fasteners that will obstruct the flow. Clothes dryer exhaust ducts shall not be connected to a vent connector, vent or chimney. Clothes dryer exhaust ducts shall not extend into or through ducts or plenums. Clothes dryer exhaust ducts shall be sealed in accordance with Section M1601.4.1.
G2439.3.1 (614.4.1) Exhaust Termination Outlet and Passageway
The passageway of dryer exhaust duct terminals shall be undiminished in size and shall provide an open area of not less than 12.5 square inches (8065 mm2).

Related Code Sections

G2439.3 Fuel Gas, (614.4) Exhaust Installation
Exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall ...
614.4 Specific Appliances, Exhaust Installation
Exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall ...
504.4 Exhaust Systems, Exhaust Installation
Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall ...
504.4 Exhaust Systems, Exhaust Installation
Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall ...
504.4 Exhaust Systems, Exhaust Installation
Exhaust duct terminations shall be in accordance with the dryer manufacturer's installation ...