M1502.3 Exhaust Ducts Shall Terminate on the Outside of the Building
JUMP TO FULL CODE CHAPTER
Exhaust duct termination s shall be in accordance
with the dryer manufacturer's installation instructions.
If the manufacturer's instructions do not specify a termination
location, the exhaust duct shall terminate no less than 3
feet (914 mm) in any direction from openings into buildings
or ventilated section in a soffit. Exhaust duct terminations
shall be equipped with a backdraft damper. Screens shall not
be installed at the duct termination.
R 408.30507
R 408.30507
Related Code Sections
M1502.3 Exhaust Systems, Exhaust Ducts Shall Terminate on the Outside of the Building
not specify a termination
location, the exhaust duct shall terminate no less than 3
feet (914 mm) in any direction from openings into buildings ...
2015 Michigan Residential Code > 15 Exhaust Systems > M1502 Clothes Dryer Exhaust > M1502.3 Exhaust Ducts Shall Terminate on the Outside of the Building
G2439.3 Fuel Gas, (614.4) Exhaust Installation
Exhaust ducts for
clothes dryers shall terminate on the outside of the building
and shall be equipped with a backdraft damper . Screens shall ...
2015 Michigan Residential Code > 24 Fuel Gas > G2439 (614) Clothes Dryer Exhaust > G2439.3 (614.4) Exhaust Installation
504.4 Exhaust Systems, Exhaust Installation
Dryer exhaust ducts for clothes
dryers shall terminate on the outside of the building, shall not
terminate within 3 feet of a ventilated section ...
2015 Michigan Mechanical Code > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.4 Exhaust Installation
409.3 Special Detailed Requirements Based on Use and Occupancy, Projection Room and Equipment Ventilation
airflow. Exhaust air ducts shall terminate at the exterior of the building in such a location that the exhaust air cannot be readily recirculated ...
2015 Michigan Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 409 Motion Picture Projection Rooms > 409.3 Projection Room and Equipment Ventilation
506.3.11 Exhaust Systems, Grease Duct Enclosures
of penetration to the outlet terminal. In-line
exhaust fans not located outdoors shall be enclosed as
required for grease ducts. A duct shall ...
2015 Michigan Mechanical Code > 5 Exhaust Systems > 506 Commercial Kitchen Hood Ventilation System Ducts and Exhaust Equipment > 506.3 Ducts Serving Type I Hoods > 506.3.11 Grease Duct Enclosures