• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2703.10.4.4 Exhaust Duct Sprinkler System Requirements

Fire Code 2018 of Kansas > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.4 Exhaust Ducts for HPM > 2703.10.4.4 Exhaust Duct Sprinkler System Requirements
JUMP TO FULL CODE CHAPTER
Automatic sprinklers installed in exhaust duct systems shall be hydraulically designed to provide 0.5 gallons per minute (gpm) (1.9 L/min) over an area derived by multiplying the distance between the sprinklers in a horizontal duct by the width of the duct. Minimum discharge shall be 20 gpm (76 L/min) per sprinkler from the five hydraulically most remote sprinklers.

2703.10.4.4.1 Sprinkler Head Locations

Automatic sprinklers shall be installed at 12-foot (3658 mm) intervals in horizontal ducts and at changes in direction. In vertical runs, automatic sprinklers shall be installed at the top and at alternate floor levels.

2703.10.4.4.2 Control Valve

A separate indicating control valve shall be provided for sprinklers installed in exhaust ducts.

2703.10.4.4.3 Drainage

Drainage shall be provided to remove sprinkler water discharged in exhaust ducts.

2703.10.4.4.4 Corrosive Atmospheres

Where corrosive atmospheres exist, exhaust duct sprinklers and pipe fittings shall be manufactured of corrosion-resistant materials or coated with approved materials.

2703.10.4.4.5 Maintenance and Inspection

Access to sprinklers in exhaust ducts shall be provided for periodic inspection and maintenance.

Related Code Sections


2703.10.4.4 Semiconductor Fabrication Facilities, Exhaust Duct Sprinkler System Requirements
Automatic sprinklers installed in exhaust duct systems shall be hydraulically designed to provide 0.5 gallons per minute (gpm) (1.9 L/min) over ...
Fire Code 2018 of Kansas > 27 Semiconductor Fabrication Facilities > 2703 General Safety Provisions > 2703.10 Automatic Sprinkler System > 2703.10.4 Exhaust Ducts for HPM > 2703.10.4.4 Exhaust Duct Sprinkler System Requirements
904.2 Fire Protection and Life Safety Systems, Where Permitted
kitchen exhaust hood and duct system required by Section 607 to have a Type I hood shall be protected with an approved automatic fire-extinguishing ...
Fire Code 2018 of Kansas > 9 Fire Protection and Life Safety Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.2 Where Permitted
22.4.2.1* Special Occupancy Requirements,
Sprinkler systems protecting stacks or ducts shall meet all of the following requirements: Sprinklers shall be spaced no more than 3.7 m (12 ft ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 22 Special Occupancy Requirements > 22.4 Spray Application Using Flammable or Combustible Materials > 22.4.2 Installation Requirements > 22.4.2.1*
904.2 Fire Protection and Life Safety Systems, Where Permitted
kitchen exhaust hood and duct system required by Section 609 of the International Fire Code or Chapter 5 of the International Mechanical Code to have ...
Building Code 2018 of Kansas > 9 Fire Protection and Life Safety Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.2 Where Permitted
22.4.2 Special Occupancy Requirements, Installation Requirements
Sprinkler systems protecting stacks or ducts shall meet all of the following requirements: Sprinklers shall be spaced no more than 3.7 m (12 ft ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 22 Special Occupancy Requirements > 22.4 Spray Application Using Flammable or Combustible Materials > 22.4.2 Installation Requirements
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE