1004 Exercise Machines and Equipment
JUMP TO FULL CODE CHAPTER
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair. Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap.
Advisory 1004.1 Clear Floor Space. One clear floor or ground space is permitted to be shared between two pieces of exercise equipment. To optimize space use, designers should carefully consider layout options such as connecting ends of the row and center aisle spaces. The position of the clear floor space may vary greatly depending on the use of the equipment or machine. For example, to provide access to a shoulder press machine, clear floor space next to the seat would be appropriate to allow for transfer. Clear floor space for a bench press machine designed for use by an individual seated in a wheelchair, however, will most likely be centered on the operating mechanisms.
Related Code Sections
1004 Recreation Facilities, Exercise Machines and Equipment
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated ...
206.2.13 Scoping Requirements, Exercise Machines and Equipment
Exercise machines and equipment required to comply with 236 shall be on an accessible route ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.2 Where Required > 206.2.13 Exercise Machines and Equipment
236 Scoping Requirements, Exercise Machines and Equipment
At least one of each type of exercise machine and equipment shall comply with 1004. Advisory 236.1 General. Most strength training equipment ...
205.1 Scoping Requirements, General
shall not be required to comply with 309.3.
Exercise machines and exercise equipment shall not be required to comply with 309.
Advisory ...
214.2 Scoping Requirements, Washing Machines
Where three or fewer washing machines are provided, at least one shall comply with 611. Where more than three washing machines are provided ...
2010 ADA Standards > 2 Scoping Requirements > 214 Washing Machines and Clothes Dryers > 214.2 Washing Machines