• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 302 Exclusion of Materials Detrimental to the Sewer System

Plumbing Code 2018 of Kansas > 3 General Regulations > 302 Exclusion of Materials Detrimental to the Sewer System
JUMP TO FULL CODE CHAPTER

302.1 Detrimental or Dangerous Materials

Ashes, cinders or rags; flammable, poisonous or explosive liquids or gases; oil, grease or any other insoluble material capable of obstructing, damaging or overloading the building drainage or sewer system, or capable of interfering with the normal operation of the sewage treatment processes, shall not be deposited, by any means, into such systems.

302.2 Industrial Wastes

Waste products from manufacturing or industrial operations shall not be introduced into the public sewer until it has been determined by the code official or other authority having jurisdiction that the introduction thereof will not damage the public sewer system or interfere with the functioning of the sewage treatment plant.

Related Code Sections


Section 302 General Regulations, Exclusion of Materials Detrimental to the Sewer System
, damaging or overloading the building drainage or sewer system, or capable of interfering with the normal operation of the sewage treatment processes ...
Plumbing Code 2018 of Kansas > 3 General Regulations > 302 Exclusion of Materials Detrimental to the Sewer System
701.5 Sanitary Drainage, Damage to Drainage System or Public Sewer
Waste detrimental to the public sewer system or to the functioning of the sewage-treatment plant shall be treated and disposed of in accordance ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 701 General > 701.5 Damage to Drainage System or Public Sewer
P2906.1.2 Water Supply and Distribution, Detrimental Condition
Where a detrimental condition exists, approved alternate materials or alternate routing shall be required ...
Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2906 Materials, Joints and Connections > P2906.1 Soil and Groundwater > P2906.1.2 Detrimental Condition
P3002.2 Sanitary Drainage, Building Sewer
Building sewer piping shall be as indicated in Table P3002.2. Forced main sewer piping shall conform to one of the standards for ABS plastic pipe ...
Residential Code 2018 of Kansas > 30 Sanitary Drainage > P3002 Materials > P3002.2 Building Sewer
702.3 Sanitary Drainage, Building Sewer Pipe
Building sewer pipe shall conform to one of the standards listed in Table 702.3. TABLE 702.3 BUILDING SEWER PIPE MATERIAL STANDARD ...
Plumbing Code 2018 of Kansas > 7 Sanitary Drainage > 702 Materials > 702.3 Building Sewer Pipe
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING