Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.331(c) Excluded Work by Qualified Persons

OSHA 1910 General Industry > S Electrical > 1910.331 Scope > 1910.331(c) Excluded Work by Qualified Persons
JUMP TO FULL CODE CHAPTER
The provisions of §§1910.331 through 1910.335 do not apply to work performed by qualified persons on or directly associated with the following installations:

1910.331(c)(1) Generation, Transmission, and Distribution Installations

Installations for the generation, control, transformation, transmission, and distribution of electric energy (including communication and metering) located in buildings used for such purposes or located outdoors.

Note 1 to paragraph (c)(1): Work on or directly associated with installations of utilization equipment used for purposes other than generating, transmitting, or distributing electric energy (such as installations which are in office buildings, warehouses, garages, machine shops, or recreational buildings, or other utilization installations which are not an integral part of a generating installation, substation, or control center) is covered under paragraph (a)(1) of this section.

Note 2 to paragraph (c)(1): For work on or directly associated with utilization installations, an employer who complies with the work practices of §1910.269 (electric power generation, transmission, and distribution) will be deemed to be in compliance with §1910.333(c) and §1910.335. However, the requirements of §1910.332, §1910.333(a), §1910.333(b), and §1910.334 apply to all work on or directly associated with utilization installations, regardless of whether the work is performed by qualified or unqualified persons.

Note 3 to paragraph (c)(1): Work on or directly associated with generation, transmission, or distribution installations includes:
  1. Work performed directly on such installations, such as repairing overhead or underground distribution lines or repairing a feed-water pump for the boiler in a generating plant.
  2. Work directly associated with such installations, such as line-clearance tree trimming and replacing utility poles, when that work is covered by § 1910.269 (see § 1910.269(a)(1)(i)(D) and (E) and the definition of "line-clearance tree trimming" in § 1910.269(x)).
  3. Work on electric utilization circuits in a generating plant provided that:

    1. Such circuits are commingled with installations of power generation equipment or circuits, and
    2. The generation equipment or circuits present greater electrical hazards than those posed by the utilization equipment or circuits (such as exposure to higher voltages or lack of overcurrent protection).
This work is covered by § 1910.269.

1910.331(c)(2) Communications Installations

Installations of communication equipment to the extent that the work is covered under §1910.268.

1910.331(c)(3) Installations in Vehicles

Installations in ships, watercraft, railway rolling stock, aircraft, or automotive vehicles other than mobile homes and recreational vehicles.

1910.331(c)(4) Railway Installations

Installations of railways for generation, transformation, transmission, or distribution of power used exclusively for operation of rolling stock or installations of railways used exclusively for signaling and communication purposes.

[55 FR 32016, Aug. 6, 1990; 59 FR 4476, Jan. 31, 1994; 79 FR 20692, Apr. 11, 2014; 80 FR 60039, October 5, 2015]

Related Code Sections


1910.331(c) Electrical, Excluded Work by Qualified Persons
The provisions of §§1910.331 through 1910.335 do not apply to work performed by qualified persons on or directly associated with the following ...
OSHA 1910 General Industry > S Electrical > 1910.331 Scope > 1910.331(c) Excluded Work by Qualified Persons
1910.333(c)(3)(ii) Electrical, Qualified Persons
When a qualified person is working in the vicinity of overhead lines, whether in an elevated position or on the ground, the person may not approach ...
OSHA 1910 General Industry > S Electrical > 1910.333 Selection and Use of Work Practices > 1910.333(c) Working on or Near Exposed Energized Parts > 1910.333(c)(3) Overhead Lines > 1910.333(c)(3)(ii) Qualified Persons
1910.265(c)(24)(iii) Special Industries, Work by Qualified Persons
Installation, inspection, maintenance, repair, and testing of ropes, cables, slings, and chains shall be done only by persons qualified to do ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(c) Building Facilities, and Isolated Equipment > 1910.265(c)(24) Ropes, Cables, Slings, and Chains > 1910.265(c)(24)(iii) Work by Qualified Persons
1910.332(b) Electrical, Content of Training
requirements for qualified persons. Qualified persons (i.e. those permitted to work on or near exposed energized parts) shall, at a minimum, be trained ...
OSHA 1910 General Industry > S Electrical > 1910.332 Training > 1910.332(b) Content of Training
1910.332(b)(3) Electrical,
Additional requirements for qualified persons. Qualified persons (i.e. those permitted to work on or near exposed energized parts) shall ...
OSHA 1910 General Industry > S Electrical > 1910.332 Training > 1910.332(b) Content of Training > 1910.332(b)(3)
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING