702.3 Estimated Wastewater Flow
JUMP TO FULL CODE CHAPTER
The estimated wastewater flow from a residence shall be 150 gallons (568 L) per bedroom per day. Wastewater flow rates for other occupancies in a 24-hour period shall be based on the values in Table 802.7.2.
Related Code Sections
702.3 Pressure Distribution Systems, Estimated Wastewater Flow
The estimated wastewater flow from a residence shall be 150 gallons (568 L) per bedroom per day. Wastewater flow rates for other occupancies in a 24 ...
Private Sewage Disposal Code 2009 > 7 Pressure Distribution Systems > 702 Design Loading Rate > 702.3 Estimated Wastewater Flow
702.3 Pressure Distribution Systems, Estimated Waste-Water Flow
The estimated wastewater flow from a residence shall be 150 gallons (568 L) per bedroom per day. Waste-water flow rates for other occupancies in a 24 ...
Private Sewage Disposal Code 2015 > 7 Pressure Distribution Systems > 702 Design Loading Rate > 702.3 Estimated Waste-Water Flow
702.2 Pressure Distribution Systems, Absorption Area
The total absorption area required shall be computed from the estimated daily wastewater flow and the design loading rate based on the percolation ...
Private Sewage Disposal Code 2012 > 7 Pressure Distribution Systems > 702 Design Loading Rate > 702.2 Absorption Area
Section 706 Pressure Distribution Systems, Dosing
The dosing frequency shall be a maximum of four times daily. A volume per dose shall be established by dividing the daily wastewater flow ...
Section 706 Pressure Distribution Systems, Dosing
The dosing frequency shall be a maximum of four times daily. A volume per dose shall be established by dividing the daily wastewater flow ...