• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3004.2 Escalators and Moving Walks

Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3004 Conveying Systems > 3004.2 Escalators and Moving Walks
JUMP TO FULL CODE CHAPTER
Escalators and moving walks shall be constructed of approved noncombustible and fire-retardant materials. This requirement shall not apply to electrical equipment, wiring, wheels, handrails and the use of 1/28-inch (0.9 mm) wood veneers on balustrades backed up with noncombustible materials.

3004.2.1 Enclosure

Escalator floor openings shall be enclosed with shaft enclosures complying with Section 713.

3004.2.2 Escalators

Where provided in below-grade transportation stations, escalators shall have a clear width of not less than 32 inches (815 mm).

Related Code Sections


10.4.4 Other Equipment, Escalators and Moving Walks
Escalators and moving walks shall automatically slow to the minimum permitted speed in accordance with ASME A17.1/CSA B44 or applicable local code ...
Energy Standard for Buildings Except Low-Rise Residential Buildings 2016 of Illinois > 10 Other Equipment > 10.4 Mandatory Provisions > 10.4.4 Escalators and Moving Walks
3004.2 Elevators and Conveying Systems, Escalators and Moving Walks
Escalators and moving walks shall be constructed of approved noncombustible and fire-retardant materials. This requirement shall not apply ...
Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3004 Conveying Systems > 3004.2 Escalators and Moving Walks
C405.8.2 [CE] Commercial Energy Efficiency, Escalators and Moving Walks
Escalators and moving walks shall comply with ASME A17.1/CSA B44 and shall have automatic controls configured to reduce speed to the minimum ...
2018 Illinois Energy Conservation Code Standards for Privately Funded Commercial Facilities and Standards for Residential Buildings > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.8 Vertical and Horizontal Transportation Systems and Equipment > C405.8.2 Escalators and Moving Walks
1003.7 Means of Egress, Elevators, Escalators and Moving Walks
Elevators, escalators and moving walks shall not be used as a component of a required means of egress from any other part of the building ...
Building Code 2018 of Illinois > 10 Means of Egress > 1003 General Means of Egress > 1003.7 Elevators, Escalators and Moving Walks
3001.3 Elevators and Conveying Systems, Referenced Standards
manlifts ASME A90.1 Conveyors and related equipment ASME B20.1 Elevators, escalators, dumbwaiters, moving walks, material lifts ASME A17.1 ...
Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3001 General > 3001.3 Referenced Standards
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE