1926.757(c) Erection of Steel Joists
Go To Full Code Chapter
1926.757(c)(1)
Both sides of the seat of one end of each steel joist that requires bridging under Tables A and B shall be attached to the support structure before hoisting cables are released.
1926.757(c)(2)
For joists over 60 feet, both ends of the joist shall be attached as specified in paragraph (b) of this section and the provisions of paragraph (d) of this section met before the hoisting cables are released.
1926.757(c)(3)
On steel joists that do not require erection bridging under Tables A and B, only one employee shall be allowed on the joist until all bridging is installed and anchored.
NM= diagonal bolted bridging not mandatory.
NM = diagonal bolted bridging not mandatory.
Joist
|
Span
|
8L1 | NM |
10K1 | NM |
12K1 | 23-0 |
12K3 | NM |
12K5 | NM |
14K1 | 27-0 |
14K3 | NM |
14K4 | NM |
14K6 | NM |
16K2 | 29-0 |
16K3 | 30-0 |
16K4 | 32-0 |
16K5 | 32-0 |
16K6 | NM |
16K7 | NM |
16K9 | NM |
18K3 | 31-0 |
18K4 | 32-0 |
18K5 | 33-0 |
18K6 | 35-0 |
18K7 | NM |
18K9 | NM |
18K10 | NM |
20K3 | 32-0 |
20K4 | 34-0 |
20K5 | 34-0 |
20K6 | 36-0 |
20K7 | 39-0 |
20K9 | 39-0 |
20K10 | NM |
22K4 | 34-0 |
22K5 | 35-0 |
22K6 | 36-0 |
22K7 | 40-0 |
22K9 | 40-0 |
22K10 | 40-0 |
22K11 | 40-0 |
24K4 | 36-0 |
24K5 | 38-0 |
24K6 | 39-0 |
24K7 | 43-0 |
24K8 | 43-0 |
24K9 | 44-0 |
24K10 | NM |
24K12 | NM |
26K5 | 38-0 |
26K6 | 39-0 |
26K7 | 43-0 |
26K8 | 44-0 |
26K9 | 45-0 |
26K10 | 49-0 |
26K12 | NM |
28K6 | 40-0 |
28K7 | 43-0 |
28K8 | 44-0 |
28K9 | 45-0 |
28K10 | 49-0 |
28K12 | 53-0 |
30K7 | 44-0 |
30K8 | 45-0 |
30K9 | 45-0 |
30K10 | 50-0 |
30K11 | 52-0 |
30K12 | 54-0 |
10KCS1 | NM |
10KCS2 | NM |
10KCS3 | NM |
12KCS1 | NM |
12KCS2 | NM |
12KCS3 | NM |
14KCS1 | NM |
14KCS2 | NM |
14KCS3 | NM |
16KCS2 | NM |
16KCS3 | NM |
16KCS4 | NM |
16KCS5 | NM |
18KCS2 | 35-0 |
18KCS3 | NM |
18KCS4 | NM |
18KCS5 | NM |
20KCS2 | 36-0 |
20KCS3 | 39-0 |
20KCS4 | NM |
20KCS5 | NM |
22KCS2 | 36-0 |
22KCS3 | 40-0 |
22KCS4 | NM |
22KCS5 | NM |
24KCS2 | 39-0 |
24KCS3 | 44-0 |
24KCS4 | NM |
24KCS5 | NM |
26KCS2 | 39-0 |
26KCS3 | 44-0 |
26KCS4 | NM |
26KCS5 | NM |
28KCS2 | 40-0 |
28KCS3 | 45-0 |
28KCS4 | 53-0 |
28KCS5 | 53-0 |
30KC53 | 45-0 |
30KCS4 | 54-0 |
30KCS5 | 54-0 |
Joist
|
Span
|
18LH02 | 33-0 |
18LH03 | NM |
18LH04 | NM |
18LH05 | NM |
18LH06 | NM |
18LH07 | NM |
18LH08 | NM |
18LH09 | NM |
20LH02 | 33-0 |
20LH03 | 38-0 |
20LH04 | NM |
20LH05 | NM |
20LH06 | NM |
20LH07 | NM |
20LH08 | NM |
20LH09 | NM |
20LH10 | NM |
24LH03 | 35-0 |
24LH04 | 39-0 |
24LH05 | 40-0 |
24LH06 | 45-0 |
24LH07 | NM |
24LH08 | NM |
24LH09 | NM |
24LH10 | NM |
24LH11 | NM |
28LH05 | 42-0 |
28LH06 | 46-0 |
28LH07 | NM |
28LH08 | NM |
28LH09 | NM |
28LH10 | NM |
28LH11 | NM |
28LH12 | NM |
28LH13 | NM |
32LH06 | 47-0 through 60-0 |
32LH07 | 47-0 through 60-0 |
32LH08 | 55-0 through 60-0 |
32LH09 | NM through 60-0 |
32LH10 | NM through 60-0 |
32LH11 | NM through 60-0 |
32LH12 | NM through 60-0 |
32LH13 | NM through 60-0 |
32LH14 | NM through 60-0 |
32LH15 | NM through 60-0 |
36LH07 | 47-0 through 60-0 |
36LH08 | 47-0 through 60-0 |
36LH09 | 57-0 through 60-0 |
36LH10 | NM through 60-0 |
36LH11 | NM through 60-0 |
36LH12 | NM through 60-0 |
36LH13 | NM through 60-0 |
36LH14 | NM through 60-0 |
36LH15 | NM through 60-0 |
1926.757(c)(4)
Employees shall not be allowed on steel joists where the span of the steel joist is equal to or greater than the span shown in Tables A and B except in accordance with § 1926.757(d).
1926.757(c)(5)
When permanent bridging terminus points cannot be used during erection, additional temporary bridging terminus points are required to provide stability. (See appendix C of this subpart.)
Upcodes Diagrams
Related Code Sections
1926.757(c) Steel Erection, Erection of Steel Joists
Both sides of the seat of one end of each steel joist that requires bridging under Tables A and B shall be attached to the support structure before ...
1926.757(d)(6) Steel Erection,
equivalents, shall be used where the bridging bolts to the steel joists ...
1926.757(d) Steel Erection, Erection Bridging
; Two rows of bolted diagonal erection bridging shall be installed near the third points of the steel joist ...
1926.757(d)(5) Steel Erection,
Where any steel joist specified in paragraphs (c)(2) and (d)(1), (d)(2), and (d)(3) of this section is a bottom chord bearing joist, a row of bolted ...
1926.757(d)(1) Steel Erection,
Where the span of the steel joist is equal to or greater than the span shown in Tables A and B, the following shall apply ...