• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2105.1.5 Equipment Maintenance and Housekeeping

Fire Code 2018 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping
JUMP TO FULL CODE CHAPTER
Proper maintenance and operating practices shall be observed in order to prevent the leakage of solvent or the accumulation of lint. The handling of waste material generated by dry cleaning operations and the maintenance of facilities shall comply with the provisions of this section.

2105.1.5.1 Floors

Class I and II liquids shall not be used for cleaning floors.

2105.1.5.2 Filters

Filter residue and other residues containing solvent shall be handled and disposed of in covered metal containers.

2105.1.5.3 Lint

Lint and refuse shall be removed from traps daily, deposited in approved waste cans, removed from the premises, and disposed of safely. At all other times, traps shall be held securely in place.

2105.1.5.4 Customer Areas

In Type V dry cleaning systems, customer areas shall be kept clean.

Related Code Sections


2105.1.5 Dry Cleaning, Equipment Maintenance and Housekeeping
Proper maintenance and operating practices shall be observed in order to prevent the leakage of solvent or the accumulation of lint. The handling ...
Fire Code 2021 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping
2105.1.5 Dry Cleaning, Equipment Maintenance and Housekeeping
Proper maintenance and operating practices shall be observed in order to prevent the leakage of solvent or the accumulation of lint. The handling ...
Fire Code 2018 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping
2105.1.5.3 Dry Cleaning, Lint
Lint and refuse shall be removed from traps daily, deposited in approved waste cans, removed from the premises, and disposed of safely. At all other ...
Fire Code 2018 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping > 2105.1.5.3 Lint
2105.1.5.4 Dry Cleaning, Customer Areas
In Type V dry cleaning systems, customer areas shall be kept clean ...
Fire Code 2021 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping > 2105.1.5.4 Customer Areas
2105.1.5.4 Dry Cleaning, Customer Areas
In Type V dry cleaning systems, customer areas shall be kept clean ...
Fire Code 2018 of Colorado > 21 Dry Cleaning > 2105 Operating Requirements > 2105.1 General > 2105.1.5 Equipment Maintenance and Housekeeping > 2105.1.5.4 Customer Areas
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING