2103.11.7.2 Epoxy Coatings
JUMP TO FULL CODE CHAPTER
Carbon steel accessories shall be epoxy-coated as follows:
1. For joint reinforcement, comply with the requirements of ASTM A 884 Class B, Type 2ā18 mils (457 m).
2. For wire ties and anchors, comply with the requirements of ASTM A 899 Class Cā20mils (508 m).
3. For sheet metal ties and anchors, provide a minimum thickness of 20 mils (508 m) or in accordance with the manufacturer's specification.
Related Code Sections
2103.11.7.2 Masonry, Epoxy Coatings
Carbon steel accessories shall be epoxy-coated as follows: 1. For joint reinforcement, comply with the requirements of ASTM A 884 Class ...
NYC Building Code 2008 > 21 Masonry > 2103 Masonry Construction Materials > 2103.11 Metal Reinforcement and Accessories > 2103.11.7 Corrosion Protection > 2103.11.7.2 Epoxy Coatings
1907.4.1 Concrete, Coatings
At the time concrete is placed, reinforcement shall be free from mud, oil or other nonmetallic coatings that decrease bond. Epoxy coatings of steel ...
NYC Building Code 2008 > 19 Concrete > 1907 Details of Reinforcement > 1907.4 Surface Conditions of Reinforcement > 1907.4.1 Coatings
1907.4.1 Concrete, Coatings
At the time concrete is placed, reinforcement shall be free from mud, oil or other nonmetallic coatings that decrease bond. Zinc and epoxy-coating ...
NYC Building Code 2014 > 19 Concrete > 1907 Details of Reinforcement > 1907.4 Surface Conditions of Reinforcement > 1907.4.1 Coatings
2107.3 Masonry, TMS 402/ACI 530/ASCE 5, Section 2.1.9.7.1.1, Lap Splices
to accomplish the same 50 percent increase shall be permitted. Where epoxy coated bars are used, lap length shall be increased by 50 percent ...
NYC Building Code 2014 > 21 Masonry > 2107 Allowable Stress Design > 2107.3 TMS 402/ACI 530/ASCE 5, Section 2.1.9.7.1.1, Lap Splices
Chapter 35 Referenced Standards [PDF] (page 5)
(Galvanized) Steel Bars for Concrete Reinforcement Specification for Epoxy-Coated Steel Reinforcing Bars Specification for Steel Sheet, 55% Aluminum-Zinc ...