2.11.13.5 Entrances With Combination Horizontally Sliding and Swinging Panels
Go To Full Code Chapter
Where both the sliding and swinging panels are not equipped with hoistway door interlocks or locks and contacts conforming to Section 2.12, the horizontally sliding and swinging panels forming a part of the entrance shall be interconnected so that
(a) the swinging panel can be opened only when the sliding panel is in the open position
(b) both panels swing as a unit