Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§1401-01 Enforcement of Fire Safety at Construction Sites

Title 3 ‒ Fire Department > 14 Fire Safety During Construction, Alteration and Demolition > §1401-01 Enforcement of Fire Safety at Construction Sites
JUMP TO FULL CODE CHAPTER
   (a)   Scope. This section sets forth requirements relating to the operation of construction sites.
   (b)   Cooperation with Department Inspections.
      (1)   Construction sites are subject to regular inspection by the Department. Such inspections may include enforcement of Construction Code requirements pursuant to the authority granted to the Department by Administrative Code §28-103.1. Inspection frequency will be determined by the Department based on an assessment of the risks associated with the construction, alteration and/or demolition work being conducted. Construction sites at which a building more than 35 feet in height or with a footprint of more than 7,500 square feet is being constructed or demolished will be inspected by the Department at least once every 30 days when construction or demolition operations are in progress, unless the Department's risk assessment of the specific construction site indicates a heightened or diminished risk warranting a different inspection frequency.
      (2)   The owner of every premises upon which construction, alteration or demolition operations are being conducted, the construction manager, project manager, general contractor and any other person in charge of such construction site, shall cooperate with the Department in its inspections of the construction site, including providing or arranging for access to and around the construction site, inspection of records, and communication with the owner or his or her design professionals, managers or contractors, as necessary or appropriate. The fire safety manager, where required pursuant to FC1408, shall provide such assistance; or, where no fire safety manager is required, such assistance shall be provided by the liaison required by FC2703.9.1.1 in connection with the storage, handling or use of hazardous materials or other appropriate representative of the owner, construction manager, project manager or general contractor.
   (c)   General Requirements. The owner shall ensure fire safety on the construction site by monitoring and enforcing compliance with all applicable code and rule provisions, including but not limited to the following requirements:
      (1)   obtaining and maintaining on the site all required permits, certificates and recordkeeping, including the Building Department work permit and Fire Department permits, in accordance with Administrative Code §§28-105.1 and 28-105.11, FC Chapter 1 and other applicable provisions of the code and rules;
      (2)   provision and maintenance of elevators in readiness, in accordance with FC1411.3 and BC3303.12;
      (3)   provision and maintenance of standpipe systems, in accordance with FC1413 and BC3303.8;
      (4)   provision and maintenance of sprinkler systems, in accordance with FC1414 and BC3306.9.6;
      (5)   provision and maintenance of stairways and other required means of egress, in accordance with FC1027 and BC3303.11;
      (6)   provision and maintenance of an approved water supply for fire protection purposes prior to delivery of hazardous materials or combustible materials at the construction site, in accordance with FC1412;
      (7)   storage, handling and use of compressed gases, including LPG and CNG, in accordance with FC 1406, 3504.2, 3804.10* and 3809.12;
      (8)   storage, handling and use of flammable liquids and combustible liquids, including gasoline, diesel fuel, paint, varnishes and lacquers, and cargo tank vehicle fueling, in accordance with FC 1405 and 3406.2;
      (9)   storage, handling and use of small arms ammunition for powder-actuated tools, including nail and rivet guns, in accordance with FC1418;
      (10)   storage, handling and use of heating, drying and curing devices, including portable fueled space heaters, in accordance with FC1403, and the enforcement of the prohibition against open fires, in accordance with FC1404;
      (11)   conduct of hot work operations, including the provision of a fire watch, in accordance with FC 1404 and 2604;
      (12)   provision, maintenance and ready availability of portable fire extinguishers, in accordance with FC906;
      (13)   provision and maintenance of fire apparatus access, in accordance with FC1410;
      (14)   provision and maintenance of an emergency telephone, in accordance with FC1409;
      (15)   storage and removal of combustible waste from the construction site, in accordance with FC1404.2;
      (16)   enforcement of the prohibition against smoking on the construction site, in accordance with FC1404; and
      (17)   provision of a watchperson familiar with the location and use of firefighting equipment and location of emergency telephone and fire alarm boxes, when construction or demolition operations are not in progress, in accordance with BC3307.5.1 and FC1409.

Related Code Sections


Article 218 Enforcement, Safety Compliance Officer
experience supervising construction projects in New York City, a licensed site safety manager or coordinator or other licensee of the department ...
NYC General Admin. Provisions 2014 > 2 Enforcement > 218 Safety Compliance Officer
Article *217 Enforcement, Safety Compliance Officer
experience supervising construction projects in New York City, a licensed site safety manager or coordinator or other licensee of the department ...
NYC General Admin. Provisions 2008 > 2 Enforcement > *217 Safety Compliance Officer
§28-218.5 Enforcement, Cost of a Safety Compliance Officer
The owner of the site where the services of the SCO have been required shall reimburse the department for all direct costs and any related ...
NYC General Admin. Provisions 2014 > 2 Enforcement > 218 Safety Compliance Officer > §28-218.5 Cost of a Safety Compliance Officer
Article 7 Administration and Enforcement, Materials, Assemblies, Forms and Methods of Construction
with the fire commissioner on all issues relating to fire safety ...
NYC 1968 Code (Vol I) > 1 Administration and Enforcement > 7 Materials, Assemblies, Forms and Methods of Construction
Article 110 Administration, Site Safety Plan
obtained regarding required safety netting during construction or demolition operations; the revised site safety plan shall be approved; Location ...
NYC General Admin. Provisions 2014 > 1 Administration > 110 Site Safety Plan
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE