1616.9.3 Energy Methods
JUMP TO FULL CODE CHAPTER
Static inelastic analysis using energy equilibrium may also be used. The structure does not need to remain elastic; however, the response ratio and rotation limits obtained from Table 1616.9.3 shall not be exceeded.
TABLE 1616.9.3 RESPONSE RATIO AND ROTATION LIMITS
TABLE 1616.9.3 RESPONSE RATIO AND ROTATION LIMITS
ELEMENT | RESPONSE RATIO | ROTATION |
Concrete slabs | µ < 10 | θ< 4° |
Post-tensioned beams | µ < 2 | θ< 1.5° |
Concrete beams | µ < 20 | θ< 6° |
Concrete columns | µ < 2 | θ< 6° |
Long span acoustical deck | µ < 2 | θ< 3° |
Open web steel joists | µ < 2 | θ< 6° |
Steel beams | µ < 20 | θ< 10° |
Steel columns | µ < 5 | θ< 6° |
For SI: 1 degree = 0.01745 rad. |
Note: Table 1616.9.3 is intended for SDOF and simplified MDOF response calculations and a low level of protection. Table 1616.9.3 does not apply for explicit finite element methods that calculate the performance of the structural elements in response to the specified loading intensity. Steel joists: downward loading 6 degrees, upward loading ductility of 2. |
Related Code Sections
1616.9.3 Structural Design, Energy Methods
Static inelastic analysis using energy equilibrium may also be used. The structure does not need to remain elastic; however, the response ratio ...
NYC Building Code 2014 > 16 Structural Design > 1616 Structural Integrity — Key Element Analysis > 1616.9 Analysis Procedures > 1616.9.3 Energy Methods
1617.8.3 Structural Design, Energy Methods
Static inelastic analysis using energy equilibrium may also be used. The structure does not need to remain elastic; however, the response ratio ...
NYC Building Code 2022 > 16 Structural Design > 1617 Structural Integrity—Key Element Analysis > 1617.8 Analysis Procedures > 1617.8.3 Energy Methods
1626.9.3 Structural Design, Energy Methods
Static inelastic analysis using energy equilibrium may also be used. The structure does not need to remain elastic; however, the response ratio ...
NYC Building Code 2008 > 16 Structural Design > 1626 Structural Integrity—Key Element Analysis > 1626.9 Analysis Procedures > 1626.9.3 Energy Methods
**§28-320.2 Maintenance of Buildings, Advisory Board
energy demand;
Methods to allow for staggered reporting cycles for compliance with energy and emissions performance improvements;
Methods ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > **§28-320.2 Advisory Board
**§28-320.2 Maintenance of Buildings, Advisory Board
year 2005. Such report shall include, but not be limited to assessments of:
Incentives for reduction of peak energy demand;
Methods to allow ...
NYC General Admin. Provisions 2022 > 3 Maintenance of Buildings > *320 Building Energy and Emissions Limits > **§28-320.2 Advisory Board