• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§28-308.2 Energy Audits Required

NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 308 Energy Audits and Retro-Commissioning of Base Building Systems > §28-308.2 Energy Audits Required
JUMP TO FULL CODE CHAPTER
The owner shall ensure that an energy audit is performed on the base building systems of a covered building prior to filing an energy efficiency report as required by this article. Except as otherwise provided in section 28-308.7, an energy audit shall be performed by or under the supervision of an energy auditor and shall be performed in accordance with rules promulgated by the department. The audit process shall cover the base building systems and shall identify at a minimum:
  1. All reasonable measures, including capital improvements, that would, if implemented, reduce energy use and/or the cost of operating the building;
  2. For each measure, the associated annual energy savings, the cost to implement, and the simple payback, calculated by a method determined by the department;
  3. The building's benchmarking output consistent with the United States Environmental Protection Agency Portfolio Manager tool or as otherwise established by the department;
  4. A break-down of energy usage by system and predicted energy savings by system after implementation of the proposed measures; and
  5. A general assessment of how the major energy consuming equipment and systems used within tenant spaces impact the energy consumption of the base building systems based on a representative sample of spaces.

Exceptions:
  1. No energy audit is required if the building complies with one of the following as certified by a registered design professional:
    1. The covered building has received an EPA Energy Star label for at least two of the three years preceding the filing of the building's energy efficiency report.
    2. There is no EPA Energy Star rating for the building type and a registered design professional submits documentation, as specified in the rules of the department, that the building's energy performance is 25 or more points better than the performance of an average building of its type over a two-year period within the three-year period prior to the filing of an energy efficiency report consistent with the methodology of the LEED 2009 rating system for Existing Buildings published by the United States Green Building Council or other rating system or methodology for existing buildings, as determined by the department.
    3. The covered building has received certification under the LEED 2009 rating system for Existing Buildings published by the United States Green Building Council or other rating system for existing buildings, as determined by the department, within four years prior to the filing of the building's energy efficiency report.
  2. An energy audit shall not be required for the first energy efficiency report of a simple building that is in compliance with six out of seven of the following items as certified by a registered design professional:
    1. Individual heating controls. (i) Each dwelling unit in the building has one or more thermostatic controls controlling all the heating units within the dwelling unit and any heated space not within a dwelling unit has one or more thermostatic controls controlling all the heating units within the space, or (ii) the building has a central heating system controlled by an energy management system or a building management system that incorporates temperature sensors located in at least 10 percent of the dwelling units and 10 percent of the heated spaces, except that the total number of sensors required within the building shall not be less than 10 nor more than 30.
    2. Common area and exterior lighting. Common area (lighting outside of tenant spaces) and exterior lighting, at a minimum, are in compliance with the provisions of the New York city energy conservation code as in effect for new systems installed on or after July 1, 2010.
    3. Low flow faucets and shower heads. All faucets and showerheads within the building, at a minimum, meet the standards of Table 604.4 of the New York city plumbing code as in effect for new systems installed on or after July 1, 2010.
    4. Pipe insulation. All exposed pipes that are used to convey heat or hot water are insulated, at a minimum, in accordance with the standards of the New York city energy conservation code as in effect for new systems installed on or after July 1, 2010.
    5. Domestic hot water. All domestic hot water tanks that do not have built-in insulation are insulated with a minimum insulation value of R-8.
    6. Washing machines. All common area clothes washing machines are front loading.
    7. Cool roof. The roof complies with section 1504.8 of the New York city building code as in effect for new buildings constructed on or after July 1, 2010.

§28-308.2.1 Contents of Audit Report

The energy auditor shall prepare and certify a report of the energy audit. Except as otherwise provided in section 28-308.7, the audit report shall include such information relating to the audit as shall be specified in the rules of the department, including but not limited to (i) the date that the audit was completed, and (ii) the information specified in section 28-308.2.

§28-308.2.1.1 Compliance With Landmarks Laws

The cost estimates for covered buildings that are regulated by any city, state or federal law regulating landmarks and historic buildings shall include all additional costs necessary for the proposed work to comply with such law.

§28-308.2.2 Timing of Energy Audit

Except as otherwise provided in section 28-308.7, the energy audit shall be completed no earlier than four years prior to the date on which a covered building's energy efficiency report is filed with the department pursuant to this article.

Related Code Sections


*§28-308.2 Maintenance of Buildings, Energy Audits Required
report as required by this article. Except as otherwise provided in section 28—308.7, an energy audit shall be performed by or under the supervision ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 308 *Energy Audits and Retro-Commissioning of Base Building Systems > *§28-308.2 Energy Audits Required
§28-308.2 Maintenance of Buildings, Energy Audits Required
report as required by this article. Except as otherwise provided in section 28-308.7, an energy audit shall be performed by or under the supervision ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 308 Energy Audits and Retro-Commissioning of Base Building Systems > §28-308.2 Energy Audits Required
§28-308.2.1.1 Maintenance of Buildings, Compliance With Landmarks Laws
The cost estimates for covered buildings that are regulated by any city, state or federal law regulating landmarks and historic buildings shall ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 308 Energy Audits and Retro-Commissioning of Base Building Systems > §28-308.2 Energy Audits Required > §28-308.2.1 Contents of Audit Report > §28-308.2.1.1 Compliance With Landmarks Laws
*§28-308.4.2 Maintenance of Buildings, Combined Audit and Retro-Commissioning
Nothing in this article shall prevent an owner from performing the audit and the retro-commissioning in a combined process, provided that all ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 308 *Energy Audits and Retro-Commissioning of Base Building Systems > *§28-308.4 Energy Efficiency Report Required > *§28-308.4.2 Combined Audit and Retro-Commissioning
§28-308.4.2 Maintenance of Buildings, Combined Audit and Retro-Commissioning
Nothing in this article shall prevent an owner from performing the audit and the retro-commissioning in a combined process, provided that all ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 308 Energy Audits and Retro-Commissioning of Base Building Systems > §28-308.4 Energy Efficiency Report Required > §28-308.4.2 Combined Audit and Retro-Commissioning
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE