• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2114.2.1.2 End Connections of Horizontal Ties

NYC Building Code 2014 > 21 Masonry > 2114 Structural Integrity Requirements > 2114.2 Continuity and Ties > 2114.2.1 Horizontal > 2114.2.1.2 End Connections of Horizontal Ties
JUMP TO FULL CODE CHAPTER
All horizontal ties shall be terminated in a perpendicular horizontal tie. Where no perpendicular horizontal tie exists within 4 feet (1219 mm) of the end of a wall, the horizontal tie shall be anchored at the end of the wall. The vertical reinforcement at the end of such walls shall not be less than two No. 4 bars placed within 16 inches (406 mm) of the end of the wall. This vertical reinforcement shall be continuous from the lowest to highest level of the wall, and anchored at each end in a horizontal tie or the foundation element.

Related Code Sections


2114.2.1.2 Masonry, End Connections of Horizontal Ties
All horizontal ties shall be terminated in a perpendicular horizontal tie. Where no perpendicular horizontal tie exists within 4 feet (1219 mm ...
NYC Building Code 2008 > 21 Masonry > 2114 Structural Integrity Requirements > 2114.2 Continuity and Ties > 2114.2.1 Horizontal > 2114.2.1.2 End Connections of Horizontal Ties
2114.2.1.2 Masonry, End Connections of Horizontal Ties
All horizontal ties shall be terminated in a perpendicular horizontal tie. Where no perpendicular horizontal tie exists within 4 feet (1219 mm ...
NYC Building Code 2014 > 21 Masonry > 2114 Structural Integrity Requirements > 2114.2 Continuity and Ties > 2114.2.1 Horizontal > 2114.2.1.2 End Connections of Horizontal Ties
Section 2114 Masonry, Structural Integrity Requirements
in the compression masonry element. The design of the end connections shall ensure the transfer of such loads to horizontal or vertical ties. Where more than one ...
NYC Building Code 2014 > 21 Masonry > 2114 Structural Integrity Requirements
2304.10.2.1 Wood, Column Connections
Girders and beams shall be closely fitted around columns and adjoining ends shall be cross tied to each other, or inter-tied by caps or ties ...
NYC Building Code 2008 > 23 Wood > 2304 General Construction Requirements > 2304.10 Heavy Timber Construction > 2304.10.2 Columns > 2304.10.2.1 Column Connections
2304.10.2.1 Wood, Column Connections
Girders and beams shall be closely fitted around columns and adjoining ends shall be cross tied to each other, or intertied by caps or ties ...
NYC Building Code 2014 > 23 Wood > 2304 General Construction Requirements > 2304.10 Heavy Timber Construction > 2304.10.2 Columns > 2304.10.2.1 Column Connections
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE