• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3202.1 Encroachments Below Grade

NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade
JUMP TO FULL CODE CHAPTER
Encroachments below grade shall comply with Sections 3202.1.1 through 3202.1.4.

3202.1.1 Footings

Exterior wall and column footings may be constructed to project beyond the street line not more than 12 inches (305 mm), provided that the top of the footing is not less than 8 feet (2438 mm) below the ground or sidewalk level. Foundation walls required to support permitted projections may be constructed to project not more than the permitted projection beyond the street line.

3202.1.1.1 Footings for Temporary Barriers or Shields in Areas of Special Flood Hazard or Shaded X-Zones

In areas of special flood hazard or shaded X-Zones, continuous footings for the support and attachment of temporary, removable dry floodproofing barriers or shields may be constructed to project beyond the street line not more than 12 inches (305 mm) both at grade and below grade.

3202.1.2 Vaults

Vaults may be permitted in accordance with the New York City Charter and Chapter 19 of the Administrative Code. Such vaults shall comply with the provisions of this code and other applicable laws and rules.

3202.1.3 Areaways

Areaways shall be protected by grates, guards or other approved means, subject to approval by the Commissioner of the Department of Transportation.

3202.1.4 Tunnels Between Buildings

Tunnels connecting buildings and projecting beyond street lines may be constructed subject to the approval of the Commissioner of the Department of Transportation. Such tunnels shall comply with the provisions of this code and other applicable laws and regulations.

3202.1.5 Sidewalk Supports

Exterior foundation walls are permitted to be constructed with a ledge that projects beyond the street line not more than 4 inches (102 mm) to support sidewalk construction, provided that:
  1. the top of the ledge is not more than 8 inches (203 mm) below the ground or sidewalk level; and
  2. bottom of the ledge is not more than 24 inches (610 mm) below the ground or sidewalk level.

Related Code Sections


3202.1 Encroachments Into the Public Right-Of-Way, Encroachments Below Grade
Encroachments below grade shall comply with Sections 3202.1.1 through 3202.1.4 ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade
3202.1 Encroachments Into the Public Right-Of-Way, Encroachments Below Grade
Encroachments below grade shall comply with Sections 3202.1.1 through 3202.1.4 ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade
3202.1.3 Encroachments Into the Public Right-Of-Way, Areaways
Areaways, subject to approval by the Commissioner of the Department of Transportation, shall be protected by grates, guards or other approved means ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade > 3202.1.3 Areaways
3202.1.3 Encroachments Into the Public Right-Of-Way, Areaways
Areaways shall be protected by grates, guards or other approved means, subject to approval by the Commissioner of the Department of Transportation ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade > 3202.1.3 Areaways
3202.1.4 Encroachments Into the Public Right-Of-Way, Tunnels Between Buildings
Tunnels connecting buildings, and projecting beyond street lines, may be constructed subject to the approval of the Commissioner of the Department ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.1 Encroachments Below Grade > 3202.1.4 Tunnels Between Buildings
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE