• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.305(e) Enclosures for Damp or Wet Locations

OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(e) Enclosures for Damp or Wet Locations
JUMP TO FULL CODE CHAPTER

1910.305(e)(1) Cabinets, Cutout Boxes, Fittings, Boxes, and Panelboard Enclosures

Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations.

1910.305(e)(2) Switches, Circuit Breakers, and Switchboards

Switches, circuit breakers, and switchboards installed in wet locations shall be enclosed in weatherproof enclosures.

Related Code Sections


1910.305(e) Electrical, Enclosures for Damp or Wet Locations
Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use > 1910.305(e) Enclosures for Damp or Wet Locations
1910.304(g)(6) Electrical, Supports, Enclosures, and Equipment to Be Grounded
contact; If located in a wet or damp location ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(g) Grounding > 1910.304(g)(6) Supports, Enclosures, and Equipment to Be Grounded
1910.304(g)(6)(vi)(C)(5) Electrical,
Cord- and plug-connected appliances used in damp or wet locations, or by employees standing on the ground or on metal floors or working inside ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(g) Grounding > 1910.304(g)(6) Supports, Enclosures, and Equipment to Be Grounded > 1910.304(g)(6)(vi) > 1910.304(g)(6)(vi)(C) If the Equipment Is of the Following Types: > 1910.304(g)(6)(vi)(C)(5)
1910.305 Electrical, Wiring Methods, Components, and Equipment for General Use
, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture ...
OSHA 1910 General Industry > S Electrical > 1910.305 Wiring Methods, Components, and Equipment for General Use
1910.304(g)(6)(vi) Electrical,
; Cord- and plug-connected appliances used in damp or wet ...
OSHA 1910 General Industry > S Electrical > 1910.304 Wiring Design and Protection > 1910.304(g) Grounding > 1910.304(g)(6) Supports, Enclosures, and Equipment to Be Grounded > 1910.304(g)(6)(vi)
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE