Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

713.12 Enclosure at Top

Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.12 Enclosure at Top
JUMP TO FULL CODE CHAPTER
A shaft enclosure that does not extend to the underside of the roof sheathing, deck or slab of the building shall be enclosed at the top with construction of the same fire-resistance rating as the topmost floor penetrated by the shaft, but not less than the fire-resistance rating required for the shaft enclosure.

Related Code Sections


713.12 Fire and Smoke Protection Features, Enclosure at Top
A shaft enclosure that does not extend to the underside of the roof sheathing, deck or slab of the building shall be enclosed at the top ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.12 Enclosure at Top
713.12 Fire and Smoke Protection Features, Enclosure at Top
A shaft enclosure that does not extend to the underside of the roof sheathing, deck or slab of the building shall be enclosed at the top ...
Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.12 Enclosure at Top
707.12 Fire-Resistance-Rated Construction, Enclosure at the Top
A shaft enclosure that does not extend to the underside of the roof sheathing, deck or slab of the building shall be enclosed at the top ...
2010 Building Code of NY > 7 Fire-Resistance-Rated Construction > 707 Shaft Enclosures > 707.12 Enclosure at the Top
2.14.1.6 Electric Elevators, Car Enclosure Tops
The car enclosure top shall be so designed and installed as to be capable of sustaining a load of 135 kg (300 lb) on any area 600 mm × 600 mm (24 ...
Safety Code for Elevators and Escalators 2016 of New York State > 2 Electric Elevators > 2.14 Car Enclosures, Car Doors and Gates, and Car Illumination > 2.14.1 Passenger and Freight Enclosures, General > 2.14.1.6 Car Enclosure Tops
5.1.11.2 Special Application Elevators, Car Enclosure Tops
Requirement 2.14.1.6 does not apply. However, if equipment is placed or installed on inclined elevators that will require servicing from the top ...
Safety Code for Elevators and Escalators 2016 of New York State > 5 Special Application Elevators > 5.1 Inclined Elevators > 5.1.11 Car Enclosures > 5.1.11.2 Car Enclosure Tops
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE