36-711 Enclosed Bicycle Parking Spaces
JUMP TO FULL CODE CHAPTER
C1 C2 C3 C4 C5 C6 C7 C8
In all districts, as indicated, enclosed accessory bicycle parking spaces shall be provided for at least that amount specified for the applicable use set forth in the table in this Section.
For the purposes of calculating the number of required bicycle parking spaces, any fraction of a space 50 percent or greater shall be counted as an additional space. For residences, the
accessory bicycle parking requirement shall be calculated separately for separate buildings or building segments.
Where any building or zoning lot contains two or more uses having different bicycle parking requirements as set forth in the table, the bicycle parking requirements for each type of use shall apply to the extent of that use.
Where an enclosed accessory group parking facility is provided, the required number of bicycle parking spaces for the use to which such facility is accessory shall be the amount set forth for such use in the table, or one for every 10 automobile parking spaces that are enclosed within a building or other structure or located on the roof of a building, whichever will require a greater number of bicycle parking spaces.
REQUIRED BICYCLE PARKING SPACES FOR RESIDENTIAL, COMMUNITY FACILITY OR COMMERCIAL USES
Type of Use | Bicycle Parking Spaces Required in Relation to Specified Unit of Measurement |
FOR RESIDENTIAL USES | |
Use Group 1 | None required |
Use Group 2 | 1 per 2 dwelling units |
Affordable independent residences for seniors | 1 per 10,000 square feet of floor area |
FOR COMMUNITY FACILITY USES1 | |
College or school student dormitories or fraternity and sorority student houses | 1 per 2,000 square of floor area |
Colleges, universities or seminaries2 | |
(a) Classrooms, laboratories, student centers or offices | 1 per 5,000 square feet of floor area |
(b) Theaters, auditoriums, gymnasiums or stadiums | 1 per 20,000 square feet of floor area |
Libraries, museums or non-commercial art galleries | 1 per 20,000 square feet of floor area |
Monasteries, convents or novitiates; required houses of worship, rectories or parish houses; Use Group 4B | None required |
All other Use Group 3 and Use Group 4 uses not otherwise listed in this table | 1 per 10,000 square feet of floor area |
FOR COMMERCIAL USES | |
Use Group 6B | 1 per 7,500 square feet of floor area |
General retail or service uses. Use Groups 5A, 6A, 6C, 6E, 7A, 7B, 7D, 8B, 9A, 10A, 12B, 13B, 14A (except docks for vessels, other than gambling vessels) or 14B; eating and drinking establishments in all Use Groups; automobile rental establishments | 1 per 10,000 square feet of floor area |
Use Groups 8A, 12A (except eating and drinking establishments); theaters | 1 per 20,000 square feet of floor area |
Public parking garages | 1 per 10 automobile parking spaces |
Use Groups not specified above, and all other commercial uses not otherwise listed | None required |
1 Non-profit hospital staff dwellings shall be subject to the requirements for Use Group 2 residential uses
2 Up to half of required spaces may be provided as unenclosed bicycle parking spaces, pursuant to the requirements of Section 36-73
However, the bicycle parking requirements set forth in the table shall be waived for bicycle parking spaces that are accessory to:
(a) buildings containing 10 dwelling units or less;
(b) colleges, universities or seminaries where the number of required enclosed bicycle parking spaces is six or less;
(c) college or school student dormitories or fraternity and sorority student houses where the number of required bicycle parking spaces is five or less; or
(d) all other community facility or commercial uses not otherwise listed in the table where the number of required bicycle parking spaces is three or less.
Related Code Sections
Article 504 Miscellaneous Provisions, *Bicycle Access to Buildings
city building code, or is operated by a freight elevator operator, and (iv) is not subject to the bicycle parking provisions of sections 25-80, 36-70 ...
Article 504 Miscellaneous Provisions, *Bicycle Access to Buildings
city building code, or is operated by a freight elevator operator, and (iv) is not subject to the bicycle parking provisions of sections 25-80, 36-70 ...
*§28-504.3 Miscellaneous Provisions, Bicycle Access Plan
of entrances; route to freight elevators that accommodate bicycle access; the route to a designated area for bicycle parking ...
NYC General Admin. Provisions 2008 > 5 Miscellaneous Provisions > 504 *Bicycle Access to Office Buildings > *§28-504.3 Bicycle Access Plan
*§28-504.1.3 Miscellaneous Provisions, Exceptions
no-cost off-street bicycle parking or sufficient secure alternate indoor no-cost bicycle parking available on the premises or within four blocks or 1,000 ...
NYC General Admin. Provisions 2014 > 5 Miscellaneous Provisions > 504 *Bicycle Access to Buildings > *§28-504.1 Bicycle Access to Certain Office Buildings > *§28-504.1.3 Exceptions
*§28-504.1.3 Miscellaneous Provisions, Exceptions
no-cost off-street bicycle parking or sufficient secure alternate indoor no-cost bicycle parking available on the premises or within four blocks or 1,000 ...
NYC General Admin. Provisions 2022 > 5 Miscellaneous Provisions > 504 *Bicycle Access to Buildings > *§28-504.1 Bicycle Access to Certain Office Buildings > *§28-504.1.3 Exceptions