Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1704.5.1 Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Buildings in Structural Occupancy Category IV

NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.5 Masonry Construction > 1704.5.1 Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Buildings in Structural Occupancy Category IV
JUMP TO FULL CODE CHAPTER
The minimum inspection program for empirically designed masonry, glass unit masonry and masonry veneer designed by Section 2109, 2110, or Chapter 14, respectively, or by Chapter 5, 6 or 7 of TMS 402/ACI 530/ASCE 5, in structures classified as structural occupancy category IV, in accordance with Table 1604.5, shall comply with Table 1704.5.1.

TABLE 1704.5.1 LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION

VERIFICATION AND INSPECTION FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA
Continuous Periodic BC Section TMS 402/ACI
530/ASCE 5a
TMS 602/ACI
530.1/ASCE 6a
1. Compliance with required inspection provisions of
the construction documents and the approved
submittals shall be verified.
— X — — Art. 1.5
2. Verification of f'm and f'AAC prior to construction
except where specifically exempted by this code.
— X — — Art. 1.4B
3. Verification of slump flow and VSI as delivered to
the site for self-consolidating grout.
X — — — Art. 1.5B.1.b.3
4. As masonry construction begins, the following shall be verified to ensure compliance:
a. Proportions of site-prepared mortar. — X — — Art. 2.6A
b. Construction of mortar joints. — X — — Art. 3.3B
c. Location of reinforcement, connectors,
prestressing tendons and anchorages.
— X — — Art. 3.4, 3.6A
d. Prestressing technique. — X — — Art. 3.6B
e. Grade and size of prestressing tendons and
anchorages.
— X — — Art. 2.4B, 2.4H
5. During construction the inspection program shall verify:
a. Size and location of structural elements. — X — — Art. 3.3F
b. Type, size and location of anchors, including
other details of anchorage of masonry to structural
members, frames or other construction.
— X — Sec. 1.2.2(e),
1.16.1
—
c. Specified size, grade and type of
reinforcement, anchor bolts, prestressing tendons
and anchorages.
— X — Sec. 1.15 Art. 2.4, 3.4
d. Welding of reinforcing bars. X — — Sec. 2.1.9.7.2,
3.3.3.4(b)
—
e. Preparation, construction and protection of
masonry during cold weather (temperature below
40°F) or hot weather (temperature above 90°F).
— X Sec. 2104.3,
2104.4
— Art. 1.8C,
1.8D
f. Application and measurement of prestressing
force.
X — — — Art. 3.6B
6. Prior to grouting, the following shall be verified to ensure compliance:
a. Grout space is clean. — X — — Art. 3.2D
b. Placement of reinforcement and connectors,
and prestressing tendons and anchorages.
— X — Sec. 1.13 Art. 3.4
c. Proportions of site-prepared grout and
prestressing grout for bonded tendons.
— X — — Art. 2.6B
d. Construction of mortar joints. — X — — Art. 3.3B
7. Grout placement shall be verified to ensure
compliance:
X — — — Art. 3.5
a. Grouting of prestressing bonded tendons. X — — — Art. 3.6C
8. Preparation of any required grout specimens,
mortar specimens and/or prisms shall be observed.
— X Sec. 2105.2.2,
2105.3
— Art. 1.4

For SI: °C = [(°F) - 32]/1.8.
a. The specific standards referenced are those listed in Chapter 35.

Related Code Sections


1704.5.1 Structural Tests and Special Inspections, Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Buildings in Structural Occupancy Category IV
The minimum inspection program for empirically designed masonry, glass unit masonry and masonry veneer designed by Section 2109, 2110, or Chapter 14 ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.5 Masonry Construction > 1704.5.1 Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Buildings in Structural Occupancy Category IV
2109.1 Masonry, General
as noted in Section 5.1.2 of TMS 402/ACI 530/ASCE 5. The use of dry-stacked, surface- bonded masonry shall be prohibited in Occupancy Category IV ...
NYC Building Code 2014 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.1 General
Section 2109 Masonry, Empirical Design of Masonry
The design or construction of masonry in buildings assigned to Seismic Design Category D as specified in Section 1616, and the design of the seismic ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry
1704.5.1 Structural Tests and Special Inspections, Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Essential Facilities
The minimum inspection program for masonry designed by Chapter 14, Section 2109 or 2110, or by Chapter 5, 6 or 7 of ACI 530/ASCE 5/TMS 402 ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.5 Masonry Construction > 1704.5.1 Empirically Designed Masonry, Glass Unit Masonry and Masonry Veneer in Essential Facilities
2109.7 Masonry, Anchorage
Existing walls of masonry units that are structurally sound ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.7 Anchorage
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE