• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 402.7.4 Emergency Voice/Alarm Communication System

Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 402 Covered Mall and Open Mall Buildings > 402.7 Emergency Systems > 402.7.4 Emergency Voice/Alarm Communication System
JUMP TO FULL CODE CHAPTER
Where the total floor area is greater than 50,000 square feet (4645 m2) within either a covered mall building or within the perimeter line of an open mall building, an emergency voice/alarm communication system shall be provided.
The fire department shall have access to any emergency voice/alarm communication systems serving a mall, required or otherwise. The systems shall be provided in accordance with Section 907.5.2.2.

Related Code Sections


907.5.2.2 Fire Protection and Life Safety Systems, Emergency Voice/Alarm Communication Systems
Emergency voice/alarm communication systems required by this code shall be designed and installed in accordance with NFPA 72. The operation of any ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.5 Occupant Notification Systems > 907.5.2 Alarm Notification Appliances > 907.5.2.2 Emergency Voice/Alarm Communication Systems
907.5.2.2 Fire Protection and Life Safety Systems, Emergency Voice/Alarm Communication Systems
Emergency voice/alarm communication systems required by this code shall be designed and installed in accordance with NFPA 72. The operation of any ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.5 Occupant Notification > 907.5.2 Alarm Notification Appliances > 907.5.2.2 Emergency Voice/Alarm Communication Systems
3008.9 Elevators and Conveying Systems, Emergency Voice/Alarm Communication System
The building shall be provided with an emergency voice/alarm communication system. The emergency voice/alarm communication system shall be accessible ...
Building Code 2021 of Illinois > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.9 Emergency Voice/Alarm Communication System
3008.9 Elevators and Conveying Systems, Emergency Voice/Alarm Communication System
The building shall be provided with an emergency voice/alarm communication system. The emergency voice/alarm communication system shall be accessible ...
Building Code 2018 of Illinois > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.9 Emergency Voice/Alarm Communication System
402.7.4 Special Detailed Requirements Based on Occupancy and Use, Emergency Voice/Alarm Communication System
mall building, an emergency voice/alarm communication system shall be provided. The fire department shall have access to any emergency voice/alarm ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 402 Covered Mall and Open Mall Buildings > 402.7 Emergency Systems > 402.7.4 Emergency Voice/Alarm Communication System
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING