• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1124A.3.4 Emergency Telephone

California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1124A Elevators and Platform (Wheelchair) Lifts > 1124A.3 Size of Cab and Control Locations > 1124A.3.4 Emergency Telephone
JUMP TO FULL CODE CHAPTER
When an emergency telephone system is installed, the emergency telephone handset shall be positioned no higher than 48 inches (1219 mm) above the floor, and the handset cord shall be a minimum of 29 inches (737 mm) in length. If the telephone system is located in a closed compartment, the compartment door hardware shall conform to the provisions of Section 1138A.4.4. Emergency intercommunication shall not require voice communication.

Related Code Sections


1124A.3.4 Housing Accessibility, Emergency Telephone
When an emergency telephone system is installed, the emergency telephone handset shall be positioned no higher than 48 inches (1219 mm) above ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1124A Elevators and Platform (Wheelchair) Lifts > 1124A.3 Size of Cab and Control Locations > 1124A.3.4 Emergency Telephone
1124A.3.4 Housing Accessibility, Emergency Telephone
When an emergency telephone system is installed, the emergency telephone handset shall be positioned no higher than 48 inches (1219 mm) above ...
California Building Code 2019 (Vol 1 & 2) > 11A Housing Accessibility > 1124A Elevators and Platform (Wheelchair) Lifts > 1124A.3 Size of Cab and Control Locations > 1124A.3.4 Emergency Telephone
3309.1 Fire Safety During Construction and Demolition, Emergency Telephone
Readily accessible emergency telephone facilities shall be provided in an approved location at the construction site. The street address ...
California Fire Code 2016 > 33 Fire Safety During Construction and Demolition > 3309 Fire Reporting > 3309.1 Emergency Telephone
3309.1 Fire Safety During Construction and Demolition, Emergency Telephone
Emergency telephone facilities with ready access shall be provided in an approved location at the construction site, or an approved equivalent means ...
California Fire Code 2019 > 33 Fire Safety During Construction and Demolition > 3309 Fire Reporting > 3309.1 Emergency Telephone
907.2.26.4 Fire Protection Systems, Emergency Telephones
A dedicated twoway emergency communication phone system designed and installed in accordance with NFPA 72 shall be provided in all underground ...
California Building Code 2016 (Vol 1 & 2) > 9 Fire Protection Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.26 Fixed-Guideway and Passenger Rail Transit Systems Fire Alarm and Communication Systems > 907.2.26.4 Emergency Telephones
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING