• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 413.8 Emergency Shutdown Control

2020 Fuel Gas Code of NYS > 4 Gas Piping Installations > 413 Compressed Natural Gas Motor Vehicle Fuel-Dispensing Facilities > 413.8 Emergency Shutdown Control
JUMP TO FULL CODE CHAPTER
An emergency shutdown device shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall also be provided in the compressor area. Upon activation, the emergency shutdown system shall automatically shut off the power supply to the compressor and close valves between the main gas supply and the compressor and between the storage containers and dispensers.

Related Code Sections


2208.7 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
An emergency shutdown control shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall also ...
2010 Fire Code of NY > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2208 Compressed Natural Gas Motor Fuel-Dispensing Facilities > 2208.7 Emergency Shutdown Control
2209.3.2.6.2.2 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
Operation of the automatic sprinkler system shall activate the emergency shutdown control required by Section 2209.5.3 ...
2010 Fire Code of NY > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2209 Hydrogen Motor Fuel-Dispensing and Generation Facilities > 2209.3 Location on Property > 2209.3.2 Location of Dispensing Operations and Equipment > 2209.3.2.6 Canopy Tops > 2209.3.2.6.2 Fire-Extinguishing Systems > 2209.3.2.6.2.2 Emergency Shutdown Control
2308.7 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
An emergency shutdown control shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall also ...
Fire Code 2015 of New York State > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2308 Compressed Natural Gas Motor Fuel-Dispensing Facilities > 2308.7 Emergency Shutdown Control
2308.7 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
An emergency shutdown control shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall ...
2020 Fire Code of NYS > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2308 Compressed Natural Gas Motor Fuel-Dispensing Facilities > 2308.7 Emergency Shutdown Control
2309.3.1.5.4 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
Operation of the automatic sprinkler system shall activate the emergency shutdown control required by Section 2309.5.3 ...
Fire Code 2015 of New York State > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2309 Hydrogen Motor Fuel-Dispensing and Generation Facilities > 2309.3 Location on Property > 2309.3.1 Location of Operations and Equipment > 2309.3.1.5 Canopy Tops > 2309.3.1.5.4 Emergency Shutdown Control
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE