• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2407.8 Emergency Shutdown

Minnesota Fire Code 2015 > 24 Flammable Finishes > 2407 Electrostatic Apparatus > 2407.8 Emergency Shutdown
JUMP TO FULL CODE CHAPTER
Electrostatic apparatus shall be equipped with automatic controls operating without time delay to disconnect the power supply to the high-voltage transformer and signal the operator under any of the following conditions:
  1. Stoppage of ventilating fans or failure of ventilating equipment from any cause.
  2. Stoppage of the conveyor carrying articles past the high-voltage grid.
  3. Occurrence of a ground or an imminent ground at any point of the high-voltage system.
  4. Reduction of clearance below that required in Section 2407.2.

Related Code Sections


2407.8 Flammable Finishes, Emergency Shutdown
Electrostatic apparatus shall be equipped with automatic controls operating without time delay to disconnect the power supply to the high-voltage ...
2020 Minnesota State Fire Code > 24 Flammable Finishes > 2407 Electrostatic Apparatus > 2407.8 Emergency Shutdown
2407.8 Flammable Finishes, Emergency Shutdown
Electrostatic apparatus shall be equipped with automatic controls operating without time delay to disconnect the power supply to the high-voltage ...
Minnesota Fire Code 2015 > 24 Flammable Finishes > 2407 Electrostatic Apparatus > 2407.8 Emergency Shutdown
2308.7 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
An emergency shutdown control shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall ...
2020 Minnesota State Fire Code > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2308 Compressed Natural Gas Motor Fuel-Dispensing Facilities > 2308.7 Emergency Shutdown Control
2308.7 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
An emergency shutdown control shall be located within 75 feet (22 860 mm) of, but not less than 25 feet (7620 mm) from, dispensers and shall also ...
Minnesota Fire Code 2015 > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2308 Compressed Natural Gas Motor Fuel-Dispensing Facilities > 2308.7 Emergency Shutdown Control
2309.3.1.5.4 Motor Fuel-Dispensing Facilities and Repair Garages, Emergency Shutdown Control
Operation of the automatic sprinkler system shall activate the emergency shutdown control required by Section 2309.5.3 ...
2020 Minnesota State Fire Code > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2309 Hydrogen Motor Fuel-Dispensing and Generation Facilities > 2309.3 Location on Property > 2309.3.1 Location of Operations and Equipment > 2309.3.1.5 Canopy Tops > 2309.3.1.5.4 Emergency Shutdown Control
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE