• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

414.2 Emergency Preparedness in Mercantile Occupancies With Comprehensive Fire Safety/Emergency Action Plans

NYC Fire Code 2014 > 4 Emergency Planning and Preparedness > 414 Mercantile Occupancies and Covered Malls > 414.2 Emergency Preparedness in Mercantile Occupancies With Comprehensive Fire Safety/Emergency Action Plans
JUMP TO FULL CODE CHAPTER
Group M occupancies that are required by FC414.2.1 to have a comprehensive fire safety and emergency action plan shall comply with the emergency preparedness requirements of this section.

414.2.1 Comprehensive Fire Safety/Emergency Action Plan (Level 1)

A comprehensive fire safety and emergency action plan in accordance with FC401.4 shall be prepared for:
  1. a high-rise Group M building.
  2. a building with one or more Group M occupancies with an aggregate area of more than 300,000 square feet (27 870 m2) on high-rise floors.
  3. a covered mall of more than 300,000 square feet (27 870 m2).

414.2.2 Fire and Life Safety Staff

The comprehensive fire safety and emergency action plan required by FC414.2.1 shall designate FLS staff consisting of an FLS director and such other FLS staff as the commissioner may prescribe by rule as appropriate for such building or occupancy, including building occupants designated by lessees of tenant spaces and similar occupancies. FLS staff shall be provided with initial and refresher FLS staff training in accordance with FC401.4.5.2.

Related Code Sections


3008.1.2 Elevators and Conveying Systems, Fire Safety and Emergency Action Plans
Code . The fire safety and emergency action plans shall incorporate specific procedures for the occupants using evacuation elevators ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.1 General > 3008.1.2 Fire Safety and Emergency Action Plans
101.4.5 Administration, Fire Prevention
; Emergency preparedness and planning, including the orderly evacuation of occupants of a building, structure or premises in the event of fire, explosion ...
NYC Building Code 2014 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.5 Fire Prevention
101.4.5 Administration, Fire Prevention
or other life safety hazards;   3. Emergency preparedness and planning, including the orderly evacuation of occupants of a building ...
NYC Building Code 2008 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.5 Fire Prevention
§28-109.3 Administration, Scope
detection equipment. Location of fire command station. Elevator recall. Emergency lighting and power. Standpipes. Sprinklers ...
NYC General Admin. Provisions 2014 > 1 Administration > 109 Fire Protection Plan > §28-109.3 Scope
*§28-109.3 Administration, Scope
The plan shall include the following information, where applicable:   1. A description of the building including: address; block and lot ...
NYC General Admin. Provisions 2008 > 1 Administration > 109 Fire Protection Plan > *§28-109.3 Scope
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE