• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

410.4 Emergency Preparedness in Educational Occupancies and Dormitories With Fire and Emergency Preparedness Plans

NYC Fire Code 2014 > 4 Emergency Planning and Preparedness > 410 Educational Occupancies > 410.4 Emergency Preparedness in Educational Occupancies and Dormitories With Fire and Emergency Preparedness Plans
JUMP TO FULL CODE CHAPTER
Educational and dormitory buildings and occupancies required by FC410.4.1 to have a fire and emergency preparedness plan shall comply with the emergency preparedness requirements of this section.

410.4.1 Fire and Emergency Preparedness Plan (Level 2)

A fire and emergency preparedness plan in accordance with FC401.5 shall be prepared for the following buildings and occupancies (other than buildings and occupancies subject to FC410.3):
  1. a high-rise Group B educational building.
  2. a high-rise Group E educational building.
  3. a Group B educational occupancy occupied or designed to be occupied by a total of more than one hundred persons on one or more high-rise floors.
  4. a Group E educational occupancy occupied or designed to be occupied by a total of more than one hundred persons on one or more high-rise floors.
  5. a high-rise Group R-1 dormitory building.
  6. a Group R-1 dormitory building or occupancy, with a total of more than fifty sleeping rooms above street level, or communal sleeping facilities above street level occupied or designed to be occupied by a total of more than fifty lodgers.

410.4.2 Fire and Emergency Preparedness Staff

The commissioner may prescribe by rule that in a Group B, E or Group R-1 dormitory building or occupancy subject to FC410.4.1 that is provided with voice communication capability there shall be present during regular business hours one or more members of the FEP staff required pursuant to FC401.5.5 who hold a certificate of fitness for emergency announcements and other fire safety duties.

410.4.3 Fire and Emergency Notice

In Group R-1 dormitory buildings or occupancies subject to FC410.4.1, a fire and emergency notice in accordance with FC405.5 shall be posted within each dwelling unit in the building or occupancy, on or immediately adjacent to the main entrance door to the dwelling unit.

Related Code Sections


101.4.5 Administration, Fire Prevention
; Emergency preparedness and planning, including the orderly evacuation of occupants of a building, structure or premises in the event of fire, explosion ...
NYC Building Code 2014 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.5 Fire Prevention
101.4.5 Administration, Fire Prevention
or other life safety hazards;   3. Emergency preparedness and planning, including the orderly evacuation of occupants of a building ...
NYC Building Code 2008 > 1 Administration > 101 General > 101.4 Referenced Codes > 101.4.5 Fire Prevention
1008.1.9.6 Means of Egress, Special Locking Arrangements in Group I-2
location. The procedures for the operation(s) of the unlocking system shall be described and approved as part of the emergency planning and preparedness ...
NYC Building Code 2014 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.9 Door Operations > 1008.1.9.6 Special Locking Arrangements in Group I-2
1604.5 Structural Design, Structural Occupancy Category and Importance Factors
greater than 500 for colleges or adult education facilities Health care facilities with an occupant load of 50 or more resident patients ...
NYC Building Code 2008 > 16 Structural Design > 1604 General Design Requirements > 1604.5 Structural Occupancy Category and Importance Factors
1604.5 Structural Design, Structural Occupancy Category
occupancies having surgery or emergency treatment facilities. Fire, rescue, ambulance and police stations and emergency vehicle garages. Designated ...
NYC Building Code 2014 > 16 Structural Design > 1604 General Design Requirements > 1604.5 Structural Occupancy Category
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE