• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3604.6 Emergency Operations Staging Areas

Fire Code 2015 of New York State > 36 Marinas > 3604 Fire Protection Equipment > 3604.6 Emergency Operations Staging Areas
JUMP TO FULL CODE CHAPTER
Space shall be provided on all float systems for the staging of emergency equipment. Emergency operation staging areas shall provide a minimum of 4 feet wide by 10 feet long (1219 mm by 3048 mm) clear area exclusive of walkways and shall be located at each standpipe hose connection. Emergency operation staging areas shall be provided with a curb or barrier having a minimum height of 4 inches (102 mm) and maximum space between the bottom edge and the surface of the staging area of 2 inches (51 mm) on the outboard sides of the staging area.

An approved sign reading FIRE EQUIPMENT STAGING AREA—KEEP CLEAR shall be provided at each staging area.

Related Code Sections


3604.6 Marinas, Emergency Operations Staging Areas
Space shall be provided on all float systems for the staging of emergency equipment. Emergency operation staging areas shall provide a minimum of 4 ...
Fire Code 2015 of New York State > 36 Marinas > 3604 Fire Protection Equipment > 3604.6 Emergency Operations Staging Areas
3604.6 Marinas, Emergency Operations Staging Areas
Space shall be provided on all float systems for the staging of emergency equipment. Emergency operation staging areas shall provide a minimum of 4 ...
2020 Fire Code of NYS > 36 Marinas > 3604 Fire Protection Equipment > 3604.6 Emergency Operations Staging Areas
410.3 Special Detailed Requirements Based on Use and Occupancy, Stages
Stage areas shall be measured to include the entire performance area and adjacent backstage and support areas ...
2010 Building Code of NY > 4 Special Detailed Requirements Based on Use and Occupancy > 410 Stages and Platforms > 410.3 Stages
410.2.7 Special Detailed Requirements Based on Occupancy and Use, Stage Ventilation
Emergency ventilation shall be provided for stages larger than 1,000 square feet (93 m 2 ) in floor area, or with a stage height greater than 50 ...
2020 Building Code of New York State > 4 Special Detailed Requirements Based on Occupancy and Use > 410 Stages, Platforms and Technical Production Areas > 410.2 Stages > 410.2.7 Stage Ventilation
410.3.7 Special Detailed Requirements Based on Use and Occupancy, Stage Ventilation
Emergency ventilation shall be provided for stages larger than 1,000 square feet (93 m 2 ) in floor area, or with a stage height greater than ...
Building Code 2015 of New York State > 4 Special Detailed Requirements Based on Use and Occupancy > 410 Stages, Platforms and Technical Production Areas > 410.3 Stages > 410.3.7 Stage Ventilation
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE