• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

416.0 Emergency Eyewash and Shower Equipment

Uniform Plumbing Code 2018 of Nevada > 4 Plumbing Fixtures and Fixture Fittings > 416.0 Emergency Eyewash and Shower Equipment
JUMP TO FULL CODE CHAPTER

416.1 Application

Emergency eyewash and shower equipment shall comply with ISEA Z358.1.

416.2 Water Supply

Emergency eyewash and shower equipment shall not be limited in the water supply flow rates. Where hot and cold water is supplied to an emergency shower or eyewash station, the temperature of the water supply shall be controlled by a temperature actuated mixing valve complying with ASSE 1071. The flow rate, discharge pattern, and temperature of flushing fluids shall be provided in accordance with ISEA Z358.1.

416.3 Installation

Emergency eyewash and shower equipment shall be installed in accordance with the manufacturer's installation instructions.

416.4 Location

Emergency eyewash and shower equipment shall be located on the same level as the hazard and accessible for immediate use. The path of travel shall be free of obstructions and shall be clearly identified with signage.

416.5 Drain

A drain shall not be required for emergency eyewash or shower equipment. Where a drain is provided, the discharge shall be in accordance with Section 811.0.

Related Code Sections


416.0 Plumbing Fixtures and Fixture Fittings, Emergency Eyewash and Shower Equipment
Emergency eyewash and shower equipment shall comply with ISEA Z358.1 ...
Uniform Plumbing Code 2018 of Nevada > 4 Plumbing Fixtures and Fixture Fittings > 416.0 Emergency Eyewash and Shower Equipment
2.1-8.4.3.8 Common Elements for Hospitals, Emergency First-Aid Equipment
: Occupational Safety and Health Standards (2) ANSI/ISEA Z358.1: American National Standard for Emergency Eyewash and Shower Equipment A2.1-8.4.3.8 ...
Guidelines for Design and Construction of Hospitals 2018 of Nevada > 2.1 Common Elements for Hospitals > 2.1-8 Building Systems > 2.1-8.4 Plumbing Systems > 2.1-8.4.3 Plumbing Fixtures > 2.1-8.4.3.8 Emergency First-Aid Equipment
2.1-8.4.3.8 Common Elements for Outpatient Facilities, Emergency First-Aid Equipment
Quick-drench emergency deluge shower and face and eyewash devices shall be provided where required by the following: *(1)  OSHA 29 CFR ...
Guidelines for Design and Construction of Outpatient Facilities 2018 of Nevada > 2.1 Common Elements for Outpatient Facilities > 2.1-8 Building Systems > 2.1-8.4 Plumbing Systems > 2.1-8.4.3 Plumbing Fixtures > 2.1-8.4.3.8 Emergency First-Aid Equipment
2.4-4.1.2.2 Specific Requirements for Critical Access Hospitals,
equipment (e.g., flood shower and eyewash station) Tele/data and electrical services ...
Guidelines for Design and Construction of Hospitals 2018 of Nevada > 2.4 Specific Requirements for Critical Access Hospitals > 2.4-4 Patient Support Facilities > 2.4-4.1 Laboratory Services > 2.4-4.1.2 Stat Laboratory > 2.4-4.1.2.2
2.1-8.4.3 Common Elements for Outpatient Facilities, Plumbing Fixtures
-drench emergency deluge shower and face and eyewash devices shall be provided where required by the following: *(1 ...
Guidelines for Design and Construction of Outpatient Facilities 2018 of Nevada > 2.1 Common Elements for Outpatient Facilities > 2.1-8 Building Systems > 2.1-8.4 Plumbing Systems > 2.1-8.4.3 Plumbing Fixtures
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING