• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R310.3 Emergency Escape and Rescue Doors

Residential Code 2018 of Kansas > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.3 Emergency Escape and Rescue Doors
JUMP TO FULL CODE CHAPTER
Where a door is provided as the required emergency escape and rescue opening, it shall be a side-hinged door or a slider. Where the opening is below the adjacent grade, it shall be provided with an area well.

R310.3.1 Minimum Door Opening Size

The minimum net clear height opening for any door that serves as an emergency and escape rescue opening shall be in accordance with Section R310.2.1.

R310.3.2 Area Wells

ILLUSTRATION
Area wells shall have a width of not less than 36 inches (914 mm). The area well shall be sized to allow the emergency escape and rescue door to be fully opened.

R310.3.2.1 Ladder and Steps

Area wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with a permanently affixed ladder or steps usable with the door in the fully open position. Ladders or steps required by this section shall not be required to comply with Section R311.7. Ladders or rungs shall have an inside width of not less than 12 inches (305 mm), shall project not less than 3 inches (76 mm) from the wall and shall be spaced not more than 18 inches (457 mm) on center vertically for the full height of the exterior stairwell.

R310.3.2.2 Drainage

Area wells shall be designed for proper drainage by connecting to the building's foundation drainage system required by Section R405.1 or by an approved alternative method.

Exception: A drainage system for area wells is not required where the foundation is on well-drained soil or sand-gravel mixture soils in accordance with the United Soil Classification System, Group I Soils, as detailed in Table R405.1.

Related Code Sections


R310.3 Building Planning, Emergency Escape and Rescue Doors
Where a door is provided as the required emergency escape and rescue opening, it shall be a side-hinged door or a slider. Where the opening is below ...
Residential Code 2018 of Kansas > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.3 Emergency Escape and Rescue Doors
Section 1002 Means of Egress, Definitions
BLEACHERS. BREAKOUT. COMMON PATH OF EGRESS TRAVEL. CORRIDOR. DOOR, BALANCED. EGRESS COURT. EMERGENCY ESCAPE AND RESCUE OPENING. EXIT. EXIT ACCESS ...
Fire Code 2018 of Kansas > 10 Means of Egress > 1002 Definitions
1002.1 Means of Egress, Definitions
BLEACHERS. BREAKOUT. COMMON PATH OF EGRESS TRAVEL. CORRIDOR. DOOR, BALANCED. EGRESS COURT. EMERGENCY ESCAPE AND RESCUE OPENING. EXIT. EXIT ACCESS ...
Fire Code 2018 of Kansas > 10 Means of Egress > 1002 Definitions > 1002.1 Definitions
1030.1 Means of Egress, General
In addition to the means of egress required by this chapter, emergency escape and rescue openings shall be provided in the following occupancies ...
Fire Code 2018 of Kansas > 10 Means of Egress > 1030 Emergency Escape and Rescue > 1030.1 General
1030.1 Means of Egress, General
In addition to the means of egress required by this chapter, emergency escape and rescue openings shall be provided in the following occupancies ...
Building Code 2018 of Kansas > 10 Means of Egress > 1030 Emergency Escape and Rescue > 1030.1 General
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE