1009.2.1 Elevators Required
Go To Full Code Chapter
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator complying with Section 1009.4.
Exceptions:
- In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit and located at or above the levels of exit discharge.
- In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp conforming to the provisions of Section 1012.
Related Code Sections
1009.2.1 Means of Egress, Elevators Required
system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a horizontal exit ...
1009.2.1 Means of Egress, Elevators Required
required accessible means of egress shall be an elevator complying with Section 1009.4. Exceptions: In buildings equipped throughout ...
506.2.1 General Site and Building Elements, Elevators Required
system installed in accordance with the applicable building code, the elevator shall not be required on floors provided with a horizontal exit ...
Section 8.4 General Requirements, Elevator Seismic Requirements
8.4, or the calculated component force level shall be used, whichever is greater.
(c) The elevator seismic requirements contained in Section 8.4 shall ...
407.2 Accessible Routes, Elevator Landing Requirements
EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.2.1.4 ...