§28-304.2 Elevators, Escalators, Moving Walkways, Material Lifts, Vertical Reciprocating Conveyors (VRC) and Dumbwaiters
JUMP TO FULL CODE CHAPTER
Elevators, escalators, moving walkways, material lifts, VRC's and dumbwaiters shall be inspected and tested in accordance with the schedule set forth in Table N1 of ASME 17.1 as referenced in chapter 35 and as may be modified in chapter 30 and appendix K of the New York city building code.
Exception: Elevators located in owner-occupied one-family, two-family or multiple-family dwellings that service only the owner-occupied dwelling unit and that are not occupied by boarders, roomers or lodgers, and elevators located within convents and rectories that are not open to non-occupants on a regular basis are not subject to periodic inspection requirement of such reference standard.
Related Code Sections
§28-304.2 Maintenance of Buildings, Elevators, Escalators, Moving Walkways, Material Lifts, Vertical Reciprocating Conveyors (VRC) and Dumbwaiters
Elevators, escalators, moving walkways, material lifts, VRC's and dumbwaiters shall be inspected and tested in accordance with the schedule set forth ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 304 Periodic Inspection of Elevators > §28-304.2 Elevators, Escalators, Moving Walkways, Material Lifts, Vertical Reciprocating Conveyors (VRC) and Dumbwaiters
§27-982 Elevators and Conveyors, Scope
, inspection, test and operation of, all elevators, dumbwaiters, escalators, moving walks, industrial lifts and loading ramps, automotive lifts, mechanical ...
§28-304.3 Maintenance of Buildings, Chair Lifts, Stairway Chair Lifts and Vertical Reciprocating Conveyors (VRCs)
Chair lifts, stairway chair lifts and VRCs shall be inspected and tested at intervals not exceeding one year. Inspections and tests shall ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > §28-304.3 Chair Lifts, Stairway Chair Lifts and Vertical Reciprocating Conveyors (VRCs)
Chapter K2 Modified Industry Standards for Elevators and Conveying Systems, Modifications to ASME B20.1-2003, Safety Standard for Conveyors and Related Equipment
) Vertical reciprocating conveyors designed to automatically receive and discharge material [may] shall have interlocked doors as in (b) above ...
NYC Building Code 2008 > K Modified Industry Standards for Elevators and Conveying Systems > K2 Modifications to ASME B20.1-2003, Safety Standard for Conveyors and Related Equipment
Chapter K2 Modified Industry Standards for Elevators and Conveying Systems, Modifications to ASME B20.1-2006, Safety Standard for Conveyors and Related Equipment
or operator, manlifts, moving walks, moving stairways (escalators), highway or railroad vehicles, cableways, tramways, dumbwaiters, pneumatic conveyors ...
NYC Building Code 2014 > K Modified Industry Standards for Elevators and Conveying Systems > K2 Modifications to ASME B20.1-2006, Safety Standard for Conveyors and Related Equipment