§28-304.2 Elevators, Escalators, Moving Walkways, Material Lifts, Man Lifts and Dumbwaiters
JUMP TO FULL CODE CHAPTER
Elevators, escalators, moving walkways, material lifts, man lifts and dumbwaiters shall be inspected and tested in accordance with the schedule set forth in Table N1 of ASME 17.1 as referenced in chapter 35 and as may be modified in chapter 30 and appendix K of the New York city building code ("Table N1").
Exception: Elevators located in one-family, two-family or multiple-family dwellings that service only a single owner-occupied dwelling unit which is not occupied by boarders, roomers or lodgers, and elevators located within convents and rectories that are not open to non-occupants on a regular basis are not subject to periodic inspection requirement of such reference standard. Inspections and tests shall be performed in accordance with Table N1.
Exception: Elevators located in one-family, two-family or multiple-family dwellings that service only a single owner-occupied dwelling unit which is not occupied by boarders, roomers or lodgers, and elevators located within convents and rectories that are not open to non-occupants on a regular basis are not subject to periodic inspection requirement of such reference standard. Inspections and tests shall be performed in accordance with Table N1.
Related Code Sections
§28-304.2 Maintenance of Buildings, Elevators, Escalators, Moving Walkways, Material Lifts, Man Lifts and Dumbwaiters
Elevators, escalators, moving walkways, material lifts, man lifts and dumbwaiters shall be inspected and tested in accordance with the schedule set ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > §28-304.2 Elevators, Escalators, Moving Walkways, Material Lifts, Man Lifts and Dumbwaiters
§28-304.2 Maintenance of Buildings, Elevators, Escalators, Moving Walkways, Material Lifts, Vertical Reciprocating Conveyors (VRC) and Dumbwaiters
Elevators, escalators, moving walkways, material lifts, VRC's and dumbwaiters shall be inspected and tested in accordance with the schedule set forth ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 304 Periodic Inspection of Elevators > §28-304.2 Elevators, Escalators, Moving Walkways, Material Lifts, Vertical Reciprocating Conveyors (VRC) and Dumbwaiters
§27-982 Elevators and Conveyors, Scope
, inspection, test and operation of, all elevators, dumbwaiters, escalators, moving walks, industrial lifts and loading ramps, automotive lifts, mechanical ...
3001.1 Elevators and Conveying Systems, Scope
, test and operation of, elevators, dumbwaiters, escalators, moving walks, industrial lifts and loading ramps, mechanical parking equipment, console ...
3001.1 Elevators and Conveying Systems, Scope
, test and operation of elevators, dumbwaiters, escalators, moving walks, industrial lifts and loading ramps, mechanical parking equipment, console ...