606.1 General
Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certificate of inspection shall be on display at all times within the elevator or attached to the escalator or dumbwaiter, be available for public inspection in the office of the building operator or be posted in a publicly conspicuous location approved by the code official. The inspection and tests shall be performed at not less than the periodic intervals listed in ASME A17.1, Appendix N, except where otherwise specified by the authority having jurisdiction.
606.2 Elevators
In buildings equipped with passenger elevators, not less than one elevator shall be maintained in operation at all times when the building is occupied.
Exception: Buildings equipped with only one elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.

Related Code Sections

Section 606 Mechanical and Electrical Requirements, Elevators, Escalators and Dumbwaiters
Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certificate of inspection shall ...
Section 606 Mechanical and Electrical Requirements, Elevators, Escalators and Dumbwaiters
Elevators, dumbwaiters and escalators shall be maintained in compliance with ASME A17.1. The most current certificate of inspection shall ...
3001.3 Elevators and Conveying Systems, Referenced Standards
manlifts ASME A90.1 Conveyors and related equipment ASME B20.1 Elevators, escalators, dumbwaiters, moving walks, material lifts ASME A17.1 ...