3002.4 Elevator Car to Accommodate Ambulance Stretcher

Building Code 2015 of Utah > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.4 Elevator Car to Accommodate Ambulance Stretcher
JUMP TO FULL CODE CHAPTER
Where elevators are provided in buildings four or more stories above, or four or more stories below, grade plane, not fewer than one elevator shall be provided for fire department emergency access to all floors. The elevator car shall be of such a size and arrangement to accommodate an ambulance stretcher 24 inches by 84 inches (610 mm by 2134 mm) with not less than 5-inch (127 mm) radius corners, in the horizontal, open position and shall be identified by the international symbol for emergency medical services (star of life). The symbol shall be not less than 3 inches (76 mm) in height and shall be placed inside on both sides of the hoistway door frame.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


3002.4 Elevators and Conveying Systems, Elevator Car to Accommodate Ambulance Stretcher
shall be provided for fire department emergency access to all floors. The elevator car shall be of such a size and arrangement to accommodate ...
Building Code 2015 of Utah > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.4 Elevator Car to Accommodate Ambulance Stretcher
408.4 Accessible Routes, Elevator Cars
Elevator cars shall comply with 408.4. Elevator ...
2010 ADA Standards > 4 Accessible Routes > 408 Limited-Use / Limited-Application Elevators > 408.4 Elevator Cars
409.4 Accessible Routes, Elevator Cars
Private residence elevator cars shall comply with 409.4 ...
2010 ADA Standards > 4 Accessible Routes > 409 Private Residence Elevators > 409.4 Elevator Cars
422.10 Fixtures, Faucets and Fixture Fittings, Special Elevations
or other location where patients are transported on a wheeled stretcher, shall be located at an elevation that prevents bumping the patient ...
Plumbing Code 2015 of Utah > 4 Fixtures, Faucets and Fixture Fittings > 422 Health Care Fixtures and Equipment > 422.10 Special Elevations
407.2.3.2 Accessible Routes, Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below ...
2010 ADA Standards > 4 Accessible Routes > 407 Elevators > 407.2 Elevator Landing Requirements > 407.2.3 Hoistway Signs > 407.2.3.2 Car Designations
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US