Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3303.2.3 Electrical Work

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.2 Utilities > 3303.2.3 Electrical Work
JUMP TO FULL CODE CHAPTER
All temporary electrical equipment and wiring shall meet the requirements of the New York City Electrical Code, and shall be maintained in compliance with such requirements. Portions of permanent electrical installations may be used for temporary operations provided the requirements of the New York City Electrical Code are met.

3303.2.3.1 Temporary Lighting for Construction Sites

Temporary lighting for construction sites shall use high-efficacy lamps with the following minimum efficacies:
  1. 60 lumens per watt for lamps over 40 watts;
  2. 50 lumens per watt for lamps over 15 watts but less than or equal to 40 watts; and
  3. 40 lumens per watt for lamps 15 watts or less.

Related Code Sections


3303.2.3 Safeguards During Construction or Demolition, Electrical Work
York City Electrical Code are met.   The person superintending the work shall notify the utility company affected at least 72 hours before ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.2 Utilities > 3303.2.3 Electrical Work
3303.2.3 Safeguards During Construction or Demolition, Electrical Work
All temporary electrical equipment and wiring shall meet the requirements of the New York City Electrical Code , and shall be maintained ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.2 Utilities > 3303.2.3 Electrical Work
§28-118.10 Administration, Electrical Work
No certificate of occupancy shall be issued unless compliance with the New York city electrical code is certified by the commissioner ...
NYC General Admin. Provisions 2014 > 1 Administration > 118 Certificates of Occupancy > §28-118.10 Electrical Work
§28-118.10 Administration, Electrical Work
No certificate of occupancy shall be issued unless compliance with the New York city electrical code is certified by the commissioner ...
NYC General Admin. Provisions 2008 > 1 Administration > 118 Certificates of Occupancy > §28-118.10 Electrical Work
§27-784 Mechanical Ventilation, Air Conditioning, and Refrigeration Systems, Electrical
All electrical work shall be installed in accordance with the requirements of the electrical code of the city of New York ...
NYC 1968 Code (Vol I) > 13 Mechanical Ventilation, Air Conditioning, and Refrigeration Systems > 5 Code Requirements of Other City Departments > §27-784 Electrical
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE