• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1006.8 Electrical Requirements

2015 Michigan Mechanical Code > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.8 Electrical Requirements
JUMP TO FULL CODE CHAPTER
The power supply to the electrical control system shall be from a two-wire branch circuit that has a grounded conductor, or from an isolation transformer with a two-wire secondary. Where an isolation transformer is provided, one conductor of the secondary winding shall be grounded. Control voltage shall not exceed 150 volts nominal, line to line. Control and limit devices shall interrupt the ungrounded side of the circuit. A means of manually disconnecting the control circuit shall be provided and controls shall be arranged so that when deenergized, the burner shall be inoperative. Such disconnecting means shall be capable of being locked in the off position and shall be provided with ready access.

Related Code Sections


1006.8 Boilers, Water Heaters and Pressure Vessels, Electrical Requirements
The power supply to the electrical control system shall be from a two-wire branch circuit that has a grounded conductor, or from an isolation ...
2015 Michigan Mechanical Code > 10 Boilers, Water Heaters and Pressure Vessels > 1006 Safety and Pressure Relief Valves and Controls > 1006.8 Electrical Requirements
306.3.1 General Regulations, Electrical Requirements
A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be provided at or near the appliance ...
2015 Michigan Mechanical Code > 3 General Regulations > 306 Access and Service Space > 306.3 Appliances in Attics > 306.3.1 Electrical Requirements
M1305.1.3.1 General Mechanical System Requirements, Electrical Requirements
A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be installed at or near the appliance ...
2015 Michigan Residential Code > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement > M1305.1.3 Appliances in Attics > M1305.1.3.1 Electrical Requirements
AJ501.5.3 Existing Building and Structures, Additional Electrical Requirements
Where the work area includes any of the following areas within a dwelling unit, the requirements of Sections AJ501.5.3.1 through AJ501.5.3.5 shall ...
2015 Michigan Residential Code > J Existing Building and Structures > AJ501 Alterations > AJ501.5 Electrical Equipment and Wiring > AJ501.5.3 Additional Electrical Requirements
415.11.10.1 Special Detailed Requirements Based on Use and Occupancy, Required Electrical Systems
in Section 2705.2.3.4 of the International Fire Code. Electrically operated systems required elsewhere in this code or in the International Fire Code ...
2015 Michigan Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.10 Emergency Power System > 415.11.10.1 Required Electrical Systems
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE