Section 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements
JUMP TO FULL CODE CHAPTER
Electrical requirements for aquatic facilities shall be in accordance with NFPA 70 or the International Residential Code, as applicable in accordance with Section 102.7.1.
Exception: Internal wiring for portable residential spas and portable residential exercise spas.
Exception: Internal wiring for portable residential spas and portable residential exercise spas.
Piping and fittings used for water service, makeup and drainage piping for pools and spas shall comply with the International Plumbing Code. Fittings shall be approved for installation with the piping installed.
Pipe, fittings and components shall be listed and labeled in accordance with NSF 50 or NSF 14. Plastic jets, fittings, and outlets used in public spas shall be listed and labeled in accordance with NSF 50.
Exceptions:
Exceptions:
- Portable residential spas and portable residential exercise spas listed and labeled in accordance with UL 1563 or CSA C22.2 No. 218.1.
- Onground storable pools supplied by the pool manufacturer as a kit that includes all pipe, fittings and components.
Piping, including process piping, that is installed in trenches, shall be inspected prior to backfilling.
Water supplies for pools and spas shall be protected against backflow in accordance with the International Plumbing Code or the International Residential Code, as applicable in accordance with Section 102.7.1.
Where waste water from pools and spas, backwash from filters and water from deck drains discharge to the building drainage system, such installation shall be in accordance with the International Plumbing Code or the International Residential Code, as applicable in accordance with Section 102.7.1.
Tests on water piping systems constructed of plastic piping shall not use compressed air for the test.
Pools and spas shall be maintained in a clean and sanitary condition, and in good repair.
An operating and maintenance manual in accordance with industry-accepted standards shall be provided for each piece of equipment requiring maintenance.
Related Code Sections
Section 302 General Compliance, Electrical, Plumbing, Mechanical and Fuel Gas Requirements
Electrical requirements for aquatic facilities shall be in accordance with NFPA 70 or the International Residential Code , as applicable ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements
302.6 General Compliance, Waste-Water Discharge
shall be in accordance with the International Plumbing Code or the International Residential Code , as applicable in accordance with Section ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements > 302.6 Waste-Water Discharge
302.7 General Compliance, Tests
Tests on water piping systems constructed of plastic piping shall not use compressed air for the test ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements > 302.7 Tests
302.8 General Compliance, Maintenance
piece of equipment requiring maintenance ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements > 302.8 Maintenance
302.8.1 General Compliance, Manuals
An operating and maintenance manual in accordance with industry-accepted standards shall be provided for each piece of equipment requiring ...
Swimming Pool and Spa Code 2015 of Massachusetts > 3 General Compliance > 302 Electrical, Plumbing, Mechanical and Fuel Gas Requirements > 302.8 Maintenance > 302.8.1 Manuals