2606.7.5 Electrical Luminaires
Go To Full Code Chapter
Light-transmitting plastic panels and light-diffuser panels that are installed in approved electrical luminaires shall comply with the requirements of Chapter 8 unless the light-transmitting plastic panels conform to the requirements of Section 2606.7.2. The area of approved light-transmitting plastic materials that is used in required exits or corridors shall not exceed 30 percent of the aggregate area of the ceiling in which such panels are installed, unless the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.
Related Code Sections
2606.7.5 Plastic, Electrical Luminaires
Light-transmitting plastic panels and light-diffuser panels that are installed in approved electrical luminaires shall comply with the requirements ...
2606.7.5 Plastic, Electrical Luminaires
Light-transmitting plastic panels and light-diffuser panels that are installed in approved electrical luminaires shall comply with the requirements ...
(1) Special Occupancies, Electrical Equipment and Sources of Ignition
Electrical equipment and other sources of ignition shall comply with the requirements of Article 502. Portable electric luminaires and other ...
(1) Special Occupancies, Electrical Equipment and Sources of Ignition
Electrical equipment and other sources of ignition shall comply with the requirements of Article 502. Portable electric luminaires and other ...
(C) Equipment for General Use, Electric-Discharge and LED Luminaires
Electric-discharge and LED luminaires shall comply with 410.62(C)(1), (C)(2), and (C)(3), as applicable ...